47
SOM-5991 User Manual
Chapter 3
A
MI BIOS
SOCKET RAPL Config
Figure 3.27 SOCKET RAPL Config
Fast_RAPL_NSTRIKE_PL2_DUTY_CYCLE
Fast_RAPL_NSTRIKE_PL2_DUTY_CYCLE value between 25 (10%) – 64
(25%).
Turbo Pwr Limit Lock
Enable or Disable locking of turbo settings.
Long Pwr Limit Ovrd
Enable or Disable Long Term Power Limit override.
Long Dur Pwr Limit
Turbo Mode Long Duration Power Limit (aka Power Limit 1) in Watts. The value
may vary from 0 to Fused Values.
Long Dur Time Window
Long Duration Time Window (aka Power Limit 1 Time) value in seconds. The
value may vary from 0 to 56.
Pkg Clmp Lim1
Pkg Clamping limit 1, allows going below P1.
Short Dur Pwr Limit En
Enable or Disable Short Duration Power Limit (aka Power Limit 2).
Short Dur Pwr Limit
Short Duration Power Limit (aka Power Limit 2) value n Watts. The value may
vary from 0 to 32767.
Pkg Clmp Lim2
Pkg Clamping limit 2, allows going below P1.