Chapter 2 Functions
1 7
2.10.2 Disk Failure Detection
The subsystem can automatically detect SCSI disk failures. The control-
ler unit monitors the disk activity like the elapsed time on all commands
issued to the disks as well SCSI bus parity error and other potential
problems.
A time-out will reset the disk and retry the command. If the command
time-out occurs again, the disk will fail. Any disk with too many errors
will be destroyed by the controller unit.
2.10.3 Cache Management
The subsystem provides data transfer performance enhancement via its
onboard cache memory. It supports up to 128MB cache memory for read
cache and write cache. Write cache policy is user selectable for maximum
performance of specific applications.
2.10.4 Read Cache
The controller unit’s read cache is always enabled. Its operation is
transparent and requires no user intervention.
2.10.5 Write Back Cache
Write back cache is a caching strategy wherein write operations result in
a completion status being sent to the host operating system as soon as
the cache (not the disk drive) receive the data to be written. The target
SCSI drive will receive the data in a more appropriate time in order to
increase the controller’s performance. To use the write back cache
function, cache must be enabled.
2.10.6 Write Through Cache
Write through cache refers to a cache writing strategy whereby data is
written to the SCSI drive before a completion status is returned to the
host operating system. This caching strategy is considered more secure
because power failure will be less likely to cause any data loss. Howev-
er, write through cache results in a slightly lower performance in most
environments. To use the write through cache function, cache must be
disabled.
Summary of Contents for RAID-800S
Page 1: ...RAID 800S SCSI to SCSI Disk Array Subsystem Installation Reference Guide ...
Page 11: ...x ...
Page 22: ...C H A P T E R 2 Functions This chapter describes the general functions of RAID 800S ...
Page 29: ...18 RAID 800S User s Manual ...
Page 40: ...Chapter 3 Installation Overview 29 Fan Figure 3 6 Location of the Fan on the Fan Holder ...
Page 43: ...32 RAID 800S User s Manual ...
Page 44: ...C H A P T E R 4 SCSI Configuration Guidelines SCSI IDs Terminators ...
Page 46: ...C H A P T E R 5 Quick Setup Guide This guide will allow you to setup RAID 800S in 5 minutes ...
Page 142: ...C H A P T E R 7 Configuring Faxes and Pagers ...
Page 173: ...162 RAID 800S User s Manual ...
Page 174: ...B Technical Specifications Array Controller Configuration A P P E N D I X ...
Page 176: ...C RAID Controller s Error Messages A P P E N D I X ...
Page 181: ...170 RAID 800S User s Manual ...
Page 182: ...E Frequently Asked Questions A P P E N D I X ...
Page 185: ...174 RAID 800S User s Manual ...