ITA-8100 / ITA-8120 User Manual

iv

16.

CAUTION: The battery is at risk of exploding if incorrectly replaced. Replace 

only with the same type recommended by the manufacturer or an equivalent. 

Discard used batteries according to the manufacturer’s instructions.

17.

 CAUTION: To avoid risk of electric shock, this equipment must only be con

-

nected to supply mains with protective earthing.

In accordance with IEC 704-1:1982 specifications, the sound pressure level at the

operator's position does not exceed 70 dB (A).
DISCLAIMER: These instructions are provided in accordance with IEC 704-1. Advan

-

tech disclaims all responsibility for the accuracy of any statements contained herein.

Consignes de sécurité

1.

Lisez attentivement ces consignes de sécurité.

2.

Gardez ce manuel pour référence future.

3.

Déconnectez cet équipement de toute prise secteur avant de le nettoyer. Utili

-

sez un chiffon humide. Ne pas utilisez de liquide ou de sprays détergents pour 

le nettoyage.

4.

La prise de courant doit être située près de l'équipement et doit être facilement 

accessible.

5.

Gardez cet équipement à l’abri de l'humidité.

6.

La chute de l’équipement pouvant l’endommager, celui-ci doit être installé sur 

une surface stable.

7.

Les ouvertures du boîtier sont nécessaires au refroidissement de l’appareil. 

Veillez à protéger l'appareil contre la surchauffe. Ne pas couvrir less ouvertures.

8.

Assurez-vous que la tension de la source d'alimentation est correcte avant de 

brancher l'appareil à la prise de courant.

9.

Placez le cordon d'alimentation de manière à éviter que des personnes 

marchent dessus. Veillez à ce qu’aucun objet ne soit placé sur le cordon d’ali

-

mentation.

10.

Tous les conseils et avertissements concernant ce matériel et son utilisation 

doivent être lus et compris.

11.

Si l'appareil n’est pas utilisé pendant une longue période, débranchez-le de la 

source d'alimentation pour éviter les dommages causés par des surtensions 

transitoires.

12.

Ne jamais verser de liquide dans une ouverture. Cela peut provoquer un 

incendie ou un choc électrique.

13.

Ne jamais ouvrir l'équipement. Pour des raisons de sécurité, l'équipement ne 

peut être ouvert que par du personnel qualifié.

14.

Si l'une des situations suivantes se présente, faites vérifier le matériel par le 

personnel de service:



Le cordon d'alimentation ou la prise est endommagé.



Du liquide a pénétré dans l'appareil.



L'équipement a été exposé à l'humidité.



L'équipement ne fonctionne pas bien, ou vous ne pouvez pas le faire 

fonctionner selon le manuel d'utilisation.



L'appareil est tombé et est endommagé.



L'équipement présente des signes évidents de casse.

15.

Ne pas laissez ce matériel dans un environnement où la température de stock

-

age peut descendre en dessous de -40 °C (-40 °F) ou être supérieure à 70 °C 

(158 °F). Ceci pourrait endommager l'équipement. L'équipement doit être main

-

tenu dans un environnement contrôlé.

Summary of Contents for ITA-8100

Page 1: ...User Manual ITA 8100 ITA 8120 Series EN 50155 10 4 12 1 Panel PC with Intel Atom Processor for Railway Applications...

Page 2: ...r the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our repair service If an Advant...

Page 3: ...ay cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating Do not cover the openings 8 Ensure that the voltage of the power source is correct before...

Page 4: ...re la surchauffe Ne pas couvrir less ouvertures 8 Assurez vous que la tension de la source d alimentation est correcte avant de brancher l appareil la prise de courant 9 Placez le cordon d alimentatio...

Page 5: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this...

Page 6: ...ery Replace the battery only with the same type recommended by the man ufacturer or an equivalent Discard used batteries according to the man ufacturer s instructions Des pr cautions sont incluses pou...

Page 7: ...ns Diagram 4 Figure 1 2 ITA 8120 Series Dimensions Diagram 5 Chapter 2 Connectors and Function Keys 7 2 1 Introduction 8 2 2 I O Connectors 8 2 3 Bezel Key Mapping 10 Chapter 3 Firmware and BIOS Infor...

Page 8: ...ITA 8100 ITA 8120 User Manual viii...

Page 9: ...Chapter 1 1 General Information Introduction Specifications System Power Safety and Environment Panel and Cutout Dimensions...

Page 10: ...tisfies EN 50155 railway regula tions 1 2 Specifications 1 2 1 System Kernel CPU Intel Atom x7 E3950 quad core processor 2 0 GHz Memory 1 x DDR3L SODIMM 4 GB default supports up to 8 GB OS Support Win...

Page 11: ...LCD Size diagonal 10 4 Resolution Pixels 1024 x 768 max Luminance 1300 nits Contrast Ratio 700 1 Backlight Adjustment Automatic with built in light sensor Manual Switched in BIOS ITA 8120 Display Typ...

Page 12: ...age 24VDC 48VDC 72VDC 110VDC 40 1 4 Safety and Environment 1 4 1 Safety FCC class A CE UL 62368 EN 50155 2017 IP65 rating front panel 1 4 2 Environment Operating Temperature 40 70 C 40 158 F 85 C 185...

Page 13: ...00 Figure 1 1 ITA 8100 Series Dimensions Diagram 310 12 205 85 3 346 85 3 346 214 8 425 295 65 11 640 85 3 346 85 3 346 6 Hole 6 5 0 256 10 0 394 70 2 756 Unit mm inch 267 10 512 186 06 7 325 14 33 0...

Page 14: ...268 108 4 4 268 260 10 236 335 7 13 215 350 13 780 108 4 4 268 108 4 4 268 10 0 394 71 5 2 815 Unit mm inch 247 9 724 125 1 4 925 125 1 4 925 11 8 0 466 6 Hol e 6 5 0 256 335 7 13 215 108 4 4 268 108...

Page 15: ...Chapter 2 2 Connectors and Function Keys Introduction I O Connectors Bezel Key Mapping...

Page 16: ...for the I O connectors and bezel key mapping to facilitate application integration 2 2 I O Connectors COM RS 422 485 Pin Number Definition Female M12 A 5P F 1 485 422_TX 2 485 422_TX 3 422_RX 4 422_RX...

Page 17: ...3 DI1 4 DI2 5 DI3 6 DI4 7 DO0 8 GND LAN Pin Number Definition Female M12 X 8P F 1 LAN_MDI0 2 LAN_MDI0 3 LAN_MDI1 4 LAN_MDI1 5 LAN_MDI3 6 LAN_MDI3 7 LAN_MDI2 8 LAN_MDI2 AUDIO Pin Number Definition Mal...

Page 18: ...ey Mapping Image Key Image Key K1 Backlight on off Reboot K17 ESC K2 SHIFT F2 K18 LEFT K3 SHIFT F3 K19 RIGHT K4 SHIFT F4 K20 UP K5 SHIFT F5 K21 DOWN K6 SHIFT F6 K22 ENTER K7 SHIFT F7 K23 1 K8 SHIFT F8...

Page 19: ...r 2 Connectors and Function Keys Press the power button K1 for less than 1 second Backlight on off Press and hold the power button K1 for 5 seconds System reboot K11 F1 K27 5 K12 F2 K28 6 K13 F3 K29 7...

Page 20: ...ITA 8100 ITA 8120 User Manual 12...

Page 21: ...Chapter 3 3 Firmware and BIOS Information DIO Setting Steps Light Sensor Enabled and Dis abled Watchdog Sample Code...

Page 22: ...t 0x29A BIT0 1 05 Read 0x299 port Read DATA from DI BIT0 1 2 4 5 Table 3 2 DIO Write DO0 High Step Action Description 00 Wait IBF clear 0x29A BIT1 0 01 Write 0xE7 to 0x29A Send DIO command 02 Wait IBF...

Page 23: ...of the ambient light The brightness can be manually adjusted by disabling the light sensor It can be set or switched in the BIOS menu Table 3 4 DIO LED High Step Action Description 00 Wait IBF clear 0...

Page 24: ...A 8120 User Manual 16 3 2 2 Disable Enable Light Sensor Enter Uncore Configuration in BIOS menu under Chipset section Inside find Brightness and set it to Auto enable light sensor or Manual disable li...

Page 25: ...17 ITA 8100 ITA 8120 User Manual Chapter 3 Firmware and BIOS Information Save desired configuration and exit BIOS to automatically restart system...

Page 26: ...Port int icount for icount 0 icount 0xFF icount int iValue inb Port if iValue OBF 0x01 return true usleep 1000 cout wait_OBF failed n cout flush return false int wait_IBF int Port int icount for icou...

Page 27: ...299 wait_IBF 0x29A outb 0x00 0x299 wait_IBF 0x29A outb 0x89 0x29A wait_IBF 0x29A outb 0x5F 0x299 wait_IBF 0x29A outb 0x64 0x299 void StartWD iopl 3 DummyPort outb 0x89 0x29A wait_IBF 0x29A outb 0x57 0...

Page 28: ...ITA 8100 ITA 8120 User Manual 20 StartWD usleep 5000000 StopWD return 0...

Page 29: ...Appendix A A Panel Mounting...

Page 30: ...ITA 8100 ITA 8120 User Manual 22 A 1 Panel Mounting M6x20L...

Page 31: ...Appendix B B DC Power Connection...

Page 32: ...Source 1 Turn off the equipment and the DC power outlet 2 Disconnect the power cable from the equipment 3 Remove the signal cables from the connectors 4 Remove the grounded cable from the equipment s...

Page 33: ...et l quipement 2 D branchez le c ble d alimentation de l quipement 3 Retirez les c bles de signal des connecteurs 4 Retirez le c ble de mise la terre de la borne de protection de mise la terre de l q...

Page 34: ...e subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permiss...

Reviews: