11
Chapter 2
In the same way, there are two kinds of BSS -- infrastructure mode and ad
hoc mode -- exist in Diagnostic Mode. Table 2.2 shows how to enter the
mode you want by adjusting the switch.
Table 2.2: Diagnostic Mode Default Setting
Diagnostic Ad hoc
Mode
Diagnostic Infrastructure Mode
SSID
WLAN
ANY
Channel
10
N/A
WEP
No
No
Enter Way
1: Power Off
2: Put switch at
Diagnostic Mode
3: Power ON and
wait for 6~10 sec-
onds for rebooting,
then the module will
be in Diagnostic Ad
hoc mode.
1: Power Off
2: Put switch at Normal Mode
3: Power ON and wait for 6~10 sec-
onds for rebooting
(*Note: Taking the step1~3 to
ensure ADAM-4570W/4571W is in
the Normal Mode)
4: Put the switch to Diagnostic
Mode, and then wait for 5 seconds.
After 5 seconds, the signal LED will
start to flash for 5 seconds. During
the 5-second interval, you have to
put the switch back to Normal Mode,
and the module will reboot to
Diagnostic Infrastructure Mode.
(*Note: If you don’t put the switch
back to Normal Mode during the 5-
second, the module will reboot to
Diagnostic Ad hoc mode.)
Note:
Please refer to Appendix A "Quick Start" if
setting or resetting the wireless connection
Summary of Contents for ADAM-4570W