background image

7

VII.  Manufacturer’s Product Warranty

 

 

Advantage Controls warrants units of its manufacture to be free of defects in material or 

workmanship.  Liability under this policy extends for 24 months from date of installation.  Liability is limited to 

repair or replacement of any failed equipment or part proven defective in material or workmanship upon 

manufacturer’s examination.  Removal and installation costs are not included under this warranty.  

Manufacturer’s liability shall never exceed the selling price of equipment or part in question.

 

Advantage disclaims all liability for damage caused by its products by improper  installation, 

maintenance, use or attempts to operate products beyond their intended  functionality, intentionally or 

otherwise, or any unauthorized repair.   Advantage is not  responsible for damages, injuries or expense 

incurred through the use of its products.

 

The above warranty is in lieu of other warranties, either expressed or implied.  No agent of ours is 

authorized to provide any warranty other than the above.

30 Day Billing Memo Policy 

 

 

Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service 

with minimum downtime.  If your unit malfunctions, call -800-743-743, and provide our technician with 

Model and Serial Number information.  If we are  unable to diagnose and solve your problem over the phone, 

a fully warranted replacement unit will be shipped, usually within 48 hours, on a 30 Day Billing Memo.

 

This service requires a purchase order and the replacement unit is billed to your regular account for 

payment.

 

The replacement unit will be billed at current list price for that model less any applicable resale 

discount.  Upon return of your old unit, credit will be issued to your account if the unit is in warranty.  If the unit 

is out of warranty or the damage not covered, a partial credit will be applied based upon a prorated 

replacement price schedule dependent on the age of the unit.  Any exchange covers only the controller 

or pump.  Electrodes, liquid end components and other external accessories are not included.

FCC Warning

This equipment generates and uses radio frequency energy and if not installed and used properly, 

that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio 

communications.  It has been type tested and found to comply with the limits for a class A computing 

device pursuant to subpart J of part 5 of FCC Rules, which are designed to provide reasonable 

protection  against  such  interference  when  operated  in  a  commercial  or  industrial  environment. 

Operation of this equipment in a residential area is likely to cause interference in which case the 

user, at his own expense, will be required to take whatever measures necessary to correct the 

interference.

Summary of Contents for NanoTron

Page 1: ...anoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P O Box 1472 Muskogee OK 74402 Phone 800 743 7431 Fax 888 686 6212 www advantagecontrols com email support advantagecontrols com 9 09 ...

Page 2: ...ion 3 II Description 3 III Installation Electrical Wiring 3 Logic and Relay Cards 4 Mounting Instructions 4 IV Front Panel Description 5 V System Operation Overview 5 Description of Menus 5 VI Menu Map 6 VII Warranty 30 Day Billing Memo Policy 7 ...

Page 3: ...3 28 Day Timer 28 day feed timers typically used for biocide feed are based on a 28 day cycle with two independent programmable feed cycles allowing for feed on selectable days and weeks 4 Batch Timer Timer activated by the Force On Off key for a user defined run time III Installation Electrical Wiring The controller has an internal regulated power supply that will operate in the range of approxim...

Page 4: ... Note Use GND and N O for N O dry contact relay or use GND and N C for N C dry contact relay Mounting Instructions Select a mounting location that provides the operator easy access to the unit and a clear view of the controls The unit should be located convenient to grounded electrical connections the required sample line plumbing and installed on a stable vertical surface WARNING Avoid locations ...

Page 5: ...lays will only be automatically active in this mode In the Run mode the display will read system values If an alarm is present the display flashes with the alarm status The Run menu will display values such as day time date and other values depending upon the features present on the unit The unit will automatically return to the Run mode if no keys are pressed for three minutes Menu This mode is u...

Page 6: ...er pulse the accumulator is number of pulses before activation If Units is pulses per gallon liter accumulator is number of gallons or liters before activation Reset Meter1 Reset Meter2 FORCE ON OFF MENU NanoTron 1 2 ENTER Wed 10 59 57am MENU FORCE ON OFF ENTER Press MENU to access menus or go back one layer in menu structure Press FORCE to activate relays manually again for Off and a third time b...

Page 7: ... If we are unable to diagnose and solve your problem over the phone a fully warranted replacement unit will be shipped usually within 48 hours on a 30 Day Billing Memo This service requires a purchase order and the replacement unit is billed to your regular account for payment The replacement unit will be billed at current list price for that model less any applicable resale discount Upon return o...

Page 8: ...all of your water treatment equipment needs Cooling Tower Controllers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems Get the Advantage ...