6
VI. Menu Map
Timer1 S
et
Timer2 S
et
C
onfigur
e
For
ce S
et
W
ater Meters
C
lo
ck S
et
S
et
Time
Set D
at
e
D
ay &
W
eek
P
ulse
R
ec
ycle
On in 0001 P
ulses
Run
Time mm:ss
O
ff
Time hh:mm
Run
Time mm:ss
28-D
ay (B
io)
E
ver
y D
ay
A:
A
ll
W
eeks
A:
Star
t 05:00a
A:
Run
Time hh:mm
A:
E
ver
y D
ay
B:
A
ll
W
eeks
B:
Star
t 05:00a
B:
Run
Time hh:mm
B:
-options-
N
o
W
eek
W
eek 1
W
eek 2
W
eek 3
W
eek 4
O
dd
W
eeks
Ev
en
W
eeks
A
ll
W
eeks
-D
ay Options-
N
o D
ay
; Sun;
M
on
Tue;
W
ed;
T
hu;
F
ri;
M,
W
, F
T, T
h,
S
M
on-F
ri
Sa
t & Sun
A
lt
er
na
te
Ev
er
yda
y
Flow SW
: Open
D
rum Lvls On
N
anoT
ron
Fir
mw
ar
e
Password 0000
Meter 1 Units
Meter2 Enabled
Meter 1 V
alue
Timer 2 Enabled
Meter 2 Units
Meter 2 V
alue
Timeout1 mm:ss
Set Force On/Of
f
key action here as:
Ask, Both, Relay 1,
Relay 2 or None.
Set
Timeout values
to desired Forced
On time for each
relay
. If a timer is a
Batch it will run for
the Batch timer
’s
run time when the
Force On/Of
f is
pressed.
Timers go back to
auto mode after
Force On/Of
f time
has expired.
Enter to access, timer type
shown, press Enter again to
change type or to settings.
If water meter
input Units is
gallons or liters
per pulse the
accumulator is
number of pulses
before activation.
If Units is pulses
per gallon/liter
accumulator is
number of gallons
or liters before
activation.
Reset Meter1?
Reset Meter2?
FO
RC
E
O
N/O
FF
M
EN
U
N
an
oT
ro
n
1
2
EN
TE
R
We
d
1
0:
59
:5
7a
m
M
EN
U
FO
RC
E
O
N/O
FF
EN
TE
R
Press MENU to access menus or go back
one layer in menu structure.
Press FORCE
to activate relays manually
again for Of
f and a third time back to auto.
Press ENTER
to go a layer deeper in menu,
to initiate a setting change and to set change.
Use up or down arrows to navigate through
menu selections or setting options.
Use left or right arrows to move curser
while making a numerical value change.
Main Menu
Circle
Tmr1 Meter1
Tmr2 WM1+2
Disabled
if 0000.
Notes:
1.
If Menu is pressed while changing a value
the value on screen will be the new value.
2.
If Timer 2 is “After Timer 1” it will activate it’s
Run each time Timer 1 completes a Run cycle.
3.
Meter units and values must be set in the
Water Meter menu for Pulse timers to work.
Select which meter(s)
contacts activate timer
.
Timer 2 has a fourth type selection;
“After
Timer 1” for sequential timers.
See note 2 below
.
B
at
ch
Run
Time mm:ss
B
at
ch timers ar
e
ac
tiv
at
ed b
y the
For
ce On/O
ff
ke
y and will r
un
for the time set
her
e.
For
ce On:
A
sk
Timeout2 mm:ss