Please read the instructions fully before

attempting installation.

IMPORTANT

This unit should be installed to current

IEE wiring regulations if in doubt

consult a qualified electrician.

Timer must not be mounted on a

flammable surface.

Ensure that the timer does not come

into contact with any combustible

materials such as towels or bedding.

Ensure at least a

300

mm air space

is allowed around the timer.

INSTALLATION /OPERATING

INSTRUCTIONS FOR

DUAL TARIFF BOOST TIMER

- T

109

-C

INSTALLATION

THIS TIMER SHOULD NOT BE

FITTED ONTO A CONDUCTIVE

SURFACE (I.E METAL)

NOTE

Use the terminals

1

to

5

as identified.

1

.

Before you begin to install.

DISCONNECT THE MAINS SUPPLY

2

.

The Dual Tariff Boost Timer is suitable

for fixed wiring only.

3

.

The following cable cross sections are

possible:

4

.

Select the single or twin box fixing

points on the plate.

5

.

If the timer is to be surface mounted:

select the single or twin fixing points

on the back plate.

6

.

Wire entry from rear, both sides

possible.

7

.

Connect main cable as shown in Fig.

5.

8.

S

elect desired flexible cable outlet to

immersion heaters and using pliers

remove the selected slot.

9

.

Clamp cables using attached cable

clamp.

10

. Connect the ‘BOOST’ and the

‘TIMED ON’ as required in Fig.

6

,

7

&

8

.

11

. Assemble the timer to the back plate

by aligning the location pins on the

top of the backplate with the cut outs

provided on the clock body. Lock in

position using a fixing screw.

Fig.

1

Fig.

2

Fig.

3

box

box

Fig.

4

3

x

2.5

mm

2

(

2

X) output

3

x

4

mm

2

(

2

X) output

Fig.

5

Fig.

6

T

wo seperate immersion heaters.

Fig.

7

Single immersion heaters.

Fig.

8

Dual immersion heaters.

T

his timer controls the use of cheap rate

electricity during the night to heat the

water in your tank for the following

applications:

BOOST LOAD

BOOST LOAD

BOOST LOAD

TIME ON LOAD

TIME ON LOAD

TIME ON LOAD

MAINS

SUPPLY

MAINS

SUPPLY

MAINS

SUPPLY

BOOST

BOOST LOAD

TIME ON LOAD

NEUTRAL

MAINS

SUPPLY

ON/OFF

SWITCH

APPLICATIONS