TECHNICAL DATA

GUARANTEE

Your KingShield Dual Tariff Boost Timer

is guaranteed for

12

months from the

date of purchase. This does not affect

your statutory rights.

TIMED ON INDICATOR

The indicator glows when the ‘TIMED

ON’ output is active.

BOOST ACTIVATOR

T

he indicator glows if the ‘BOOST

SWITCH’ is used.

ON/OFF SWITCH - SWITCH IS IN ‘OFF

POSITION’

The settings of the ‘TIMED ON’and

‘BOOST’ time period are not activated

the clock runs but the heater is

disconnected.

SWITCH IS IN ‘ON POSITION’

The settings of the ‘TIMED ON’ AND

‘BOOST’ time period are activated and

the water will be heated during the

‘TIMED ON’ time period.

BOOST BUTTON

1

.

This button is only needed if you

need extra hot water during the day

time ‘PEAK’ time.

2

.

Choose your boost time (adjustable

between

15

&

120

minutes). Press

the ‘

BOOST BUTTON

’ once for

switching ON.

3

.

If you want to interrupt the boost

function before the boost time is

completed: Press the ‘

BOOST

BUTTON

’ again.

CHANGING THE ‘TIMED ON’ TIME
PERIOD

To set the time on period, move the

tappets for the ‘TIMED ON’ time period

to the outer position of the dial. The

minimum switching time is

15

minutes.

SETTING THE TIME OF DAY

Turn the dial in the direction of the arrow

(clockwise) until the correct time of day is

exactly opposite the time set marker on

the clockface (

24

hr clock).

FITTING THE SEE-THROUGH COVER

1

.

Once the see through cover is

located, it can be removed using a

screwdriver.

2

.

Align the bar on the edge of the cover

with the groove at the lower end of

the dial in the housing.

3

.

Remove the cover by applying a

screwdriver between groove and

cover.

Fig.

10

Fig.

11

Boost

Indicator

Boost

Button

On/Off

Switch

Timed on

Indicator

Clock with

Tappets

HEATER CONTROLLER AT A GLANCE

Fig.

9

Rated Voltage:

230

V, AC

50Hz

M

ax Current:

16A

resistive,

2

A Inductive

Ambient Temp:

-

10

°C to +

55

°C

Rating:

16

A for immersion

heaters upto

3.5

Kw

Boost:

Adjustable between

15

and

120

minutes

Fitting:

Surface mounted

Dimensions:

86

H x

155

W x

55

D (mm)

Protection Category:

IP

20