Installation Guide V1.2
7
5 - DAIKIN (CB7 DK) SETUP
CB7 DK setup steps are as follows:
1. Connect the Daikin wired remote to the indoor unit in the roof space.
2. Power up the air conditioner & run the unit to test correct operation of indoor &
outdoor unit.
3. Using the Daikin wired remote change the
fi
eld settings for use with either the
Return Air Sensor or a MyZone Sensor (if supplied)
How to set Daikin
fi
eld settings:
a. Press and hold the CANCEL Button (bottom right corner button)
b. Select Field setting list and press MENU/ENTER (middle round button)
c. Use the UP / DOWN buttons to select the Menu number.
d. Press the LEFT / RIGHT buttons to select the Setting.
e. Press the UP / DOWN buttons to change the Value.
f. Press MENU / ENTER button (middle round button) to save this setting.
g. Select YES to the question “Is it settled by setting?”
h. Repeat for any other required
fi
eld settings.
4. Power off the Daikin air conditioner & remove Daikin wired remote control from
system.
5. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores
to the terminals as shown below:
CABLE CORE COLOUR
INDOOR UNIT TERMINAL
RED
P1
BLACK
P2
6. Go to Section 15 SYSTEM CONFIGURATION to complete install.
Return Air Sensor
Menu
20
2
02
Setting
Value
MyZone Sensor
22
6
01
Menu
20
2
03
Setting
Value
22
6
01
Summary of Contents for MyAir