Installation Guide V1.2
14
15 - SYSTEM CONFIGURATION
Now the CB7 (and variants) have been paired to the indoor unit. The following
steps will complete the system con
fi
guration.
IMPORTANT: Due to heat transfer in summer, the CB should be installed at
least 1m away from roofing materials, such as roof tiles.
1. Connect the zone motors, touch screen and antenna
NOTE: Antenna only supplied when wireless temperature sensors are ordered
IMPORTANT: Keep control cables, such as the TSP cable and the indoor unit link
cable, away from other 240V cables or devices.
2. Check System ID, the System ID dipswitch is found
on the CB. If there are multiple systems in one
install then the System ID for each CB must be set
to a different switch combination. The System ID
may also need to be changed if a clash occurs with
nearby installations.
3. Check the Settings dipswitch:
• Switch no. 2 must be in the ON position,
• Switch no. 5 must be
ON
to use the Return
Air Sensor OR in the
OFF
position to use a
MyZone Sensor.
NOTE: For Fujitsu units only, Auto Field Settings are disabled when switch no. 10 is
in the ON position.
4. Plug power supply into control box.
IMPORTANT: The power transformer (PSU-ACDC) must be plugged into a surge
protected power outlet/point.
5. Con
fi
gure a sensor for each zone.
• Wireless
a. Set the System ID on each sensor to match your control box.
b. Set the zone number by
fl
icking the appropriate switch on (eg if you
would like to set a sensor as zone 6 you would
fl
ick only switch 6 ON.)
• Wired
Set the zone number by
fl
icking the appropriate switch on (eg if you would
like to set a sensor as zone 6 you would
fl
ick only switch 6 ON.)
Continues over page...