Installation Guide V1.2
10
10 - PANASONIC (CB7 PA) SETUP
CB7 PA setup steps are as follows:
1. Connect the Panasonic wired remote to the indoor unit in the roof space.
2. Using the Panasonic wired remote change the
fi
eld settings for use with either
the Return Air Sensor or a MyZone Sensor (if supplied)
How to set Panasonic
fi
eld settings for Menu’s 1 & 2:
3. Power off the Panasonic air conditioner & remove Panasonic wired remote
control from system.
4. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores
to the terminals as shown below:
CABLE CORE COLOUR
INDOOR UNIT TERMINAL
RED
R1
BLACK
R2
5. Go to Section 15 SYSTEM CONFIGURATION to complete install
Panasonic Remote
CZ-RTC2
Menu
Setting
Value
Return Air Sensor
2
32
0000
1
01
0001
Menu
Setting
Value
MyZone Sensor
2
32
0001
1
01
0001
Menu
1
0A
0000
Setting
Value
Return Air Sensor
2
32
0000
1
01
0001
Menu
1
0A
0001
Setting
Value
MyZone Sensor
2
32
0001
1
01
0001
Panasonic Remote
CZ-RTC4
Menu 1
a. Press and hold the MODE (Top Right) &
TIMER SET buttons together for 5 seconds.
b. Use UP & DOWN TEMPERATURE buttons
to change the 1st value
c. Use UP & DOWN TIMER buttons to change
the 2nd value
d. When you are done press the SET button
e. Repeat from step b to set second required
code
f. Press the SPANNER button to return to
main screen
Menu 2
a. Press and hold the SPANNER, SET &
CANCEL buttons together for 5 seconds.
b. Use UP & DOWN TEMPERATURE buttons
to change the 1st value
c. Use UP & DOWN TIMER buttons to change
the 2nd value
d. When you are done press the SET button
e. Press the SPANNER button to return to
main screen