CONFIGURATION
Configuration Setup
ID
Description
Default
Min
Max
P0
Number of vent motor circuits
2
0
3
P1
Number of fan circuits
0
0
6
P3
Number of heaters
2
0
4
P6
Wind average minutes. The response time for wind to
average out the gusts
3
1
5
P7
Wind wheel calibration 25=MPH 17=KPH
25
P10
Type of 2nd sensor
0 = none, 1 = humidty, 2 = amps, 3 = temperature
0
P18
How many vent motors are in zone2
0
P19
Max seconds vent motors will close for rain or high wind
250
P25
Is anemometer connected to Input#2
No
P26
Do you want ability for fans to turn off at high temperature?
(If you have smaller fans that need to turn off when larger
fans turn on)
No
P28
Farenheit or Celsuis
F
P30
Revert controller to defaults
P34
Fan#1 input. If fan should turn off if an Input is on
1 = off if input #1 is on, 2 = off if input#2 is on
0
2
P35 - P39
Remaining fan’s inputs , see P34
0
2
P40
Vent Motor #1 rain sensor uses input #
You select which input curtain#1’s rain sensor is connected
0
2
P41
Vent Motor #2 rain sensor uses input #
You select which input curtain#2’s rain sensor is connected
0
2
P42
Vent Motor#3 rain sensor uses input #
You select which input curtain#3’s rain sensor is connected
0
2
P43
Humidity Vent, which vent motor will open if humidity gets
too high.
16