2.4.2
Default Alarm Setting
Setting Value
Control Item
Downlink Uplink
RSSI
-95 dBm
-110 dBm
Input Overload
-35 dBm
-35 dBm
Heartbeat On/Off
ON
Heartbeat Time
20 minutes
Table 10 - Default Alarm Parameter Values of the Epoch-M1C Software