Epoch-M1C RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document
Page 19 of 38
Uplink Tracking/Offset Modes
Uplink tracking mode enables or disables the
Uplink Tracking ON feature that
sets the gain in the uplink equaling to the gain in the downlink. The tracking
gain offset is the difference between the uplink and downlink gains. For
example, if the downlink gain is 80 dB, the
Uplink Tracking ON is checked, and
the
Uplink Tracking Gain Offset is set to 3 dB, the uplink gain would be 77 dB.
By default, the
Uplink Tracking ON box is not checked. If it was checked, then
the default
Uplink Tracking Offset is set to 3 dB. This means that the uplink gain
will track the down link gain and will be 3 dB less.
Control Item
Action
Setting Value
Uplink Tracking ON
Set Uplink Tracking Mode
ON or OFF
Uplink Tracking Offset
Set Tracking Gain Offset
0 ~ 10 dB @ 0.5 dB step
Downlink/Uplink Gain
The gain of the Epoch-M1C is the ratio of the input signal to the output signal.
The gain may be set in both links.
** The manual gain option is disabled when the AGC ON box is checked.
Reboot
By clicking the “Reboot” button, similar to how the operation works in a PC, the
control board of the repeater will restart itself
.
Factory Setting
Clicking on the “Factory Setting”
button resets the settings of the repeater to the
original default factory settings as noted in the “Default Control Settings” in
Section 2.4 on page 28.
** You will lose your current saved settings once you click on Factory Setting.
Table 3 - Uplink Tracking Mode and Tracking Gain Offset Range