Specifications
2-1
Machine Dimensions
Length: 88”
Height: 60”
Depth: 38”
Weight: 2100 lbs.
Electrical Requirements
220/230 VAC single phase, 50/60 Hz, 60 Amp service.
Pneumatic Requirements
Approximately 2-3 cfm at 60-90 psi line pressure supplied via your cleaned/dried/regulated plant air.
Material Capacity
Upper Front Station:
10” Diameter x 60 long x 3” Diameter core.
Lower Front Station:
10” Diameter x 60 long x 3” Diameter core. (Thermal)
10” Diameter x 61 long x 3” Diameter core. (Pressure Sensitive)
Upper Rear Station:
10” Diameter x 60 long x 3” Diameter core. (Thermal)
10” Diameter x 61 long x 3” Diameter core. (Pressure Sensitive)
Lower Rear Station:
10” Diameter x 60 long x 3” Diameter core.
Middle Front Station:
8” Diameter x 60 long x 3” Diameter core. (Thermal)
8” Diameter x 61 long x 3” Diameter core. (Pressure Sensitive)
These are physical dimension restrictions. The weight of the supply roll should never exceed 90 lbs.