Installation
1-2
Electrical Connection
Refer to the
Electrical Requirements
under Specifications for the proper requirements for your
laminator. All connections to components and terminal blocks should be checked for tightness before
initial startup. This will help avoid and electrical problems caused by connections that may have loosened
due to vibration during shipping. A readily accessible disconnect device shall be incorporated into the
fixed wiring circuit. The switch on the laminator is not considered a disconnect device. Consult a
qualified, licensed electrician to ensure that the power supply for the machine is properly installed in your
facility. Qualified personnel can remove the RH enclosure cover to allow access to the terminal strip and
grounding lug. Advanced Grieg Laminators, Inc. will not be responsible for damage caused by incorrect
electrical installation.
Pneumatic Connection
Refer to the Pneumatic Requirements under Specifications for the proper requirements for your laminator.
The air supply should be clean, dry, and regulated. Failure to properly clean and dry the air supplied to
the laminator will cause damage to the cylinders. The laminator is supplied with a 1/4npt port for your
final connection.
The air supply to the laminator must be clean and dry. Particles and
moisture can damage the cylinders
.
Recycling Packaging
If your machine came in a fully enclosed crate, the crate can be stored flat for future use or dismantled
and the wood can be recycled. The screws can be kept for future use of the crates or stored for some
other use. The shrink wrap is not recyclable and should be thrown away. The foam protective coverings
over the rolls can be recycled to be used for other shipping purposes.