Table 11. Parameter list (Continued)
API
#
Read /
Write
Address
Parameter Name
Type
Parameter Description
Dec
Hex
46
Read
4202
106A
Device error extension r UINT32
Error extension - read
Bit 1: Extension card X53 error
Bit 2: Extension card X54 error
Bit 3: External extension 1 error
Bit 4: External extension 2 error
Bit 5: dASM card error
Bit 6: Anybus module error
Bit 8: dASM total power exceeded
Bit 9: dASM count error
47
4204
106C
48
Read
4206
106E
#1 Analog setpoint r
FLOAT
Power controller #1: Analog setpoint -
read
49
Read
4208
1070
#1 Motor pot. setpoint r
FLOAT
Power controller #1: Motor
potentiometer setpoint - read
50
Write
4210
1072
#1 Fieldbus setpoint w
FLOAT
Power controller #1: Fieldbus setpoint -
write
51
Read
4212
1074
#1 Actual setpoint r
FLOAT
Power controller #1: Actual setpoint -
read
52
Write
4214
1076
#1 Error setpoint w
FLOAT
Power controller #1: Error setpoint -
write
53
Read
4216
1078
#1 Total power r
FLOAT
Power controller #1: Total power - read
54
Read
4218
107A
#1 Alpha r
FLOAT
Power controller #1: Alpha - read
55
Read
4220
107C
#1 TimeOn r
FLOAT
Power controller #1: Time on - read
56
Read
4222
107E
#1 Output r
FLOAT
Power controller #1: Output - read
57
Read
4224
1080
#1 Frequency r
FLOAT
Power controller #1: Frequency - read
58
Read
4226
1082
#1 Energy counter r
FLOAT
Power controller #1: Energy counter -
read
Advanced Energy
®
Thyro-PX
™
Anybus
®
Modbus TCP
57010166-00A
Thyro-PX
™
Anybus
®
Modbus TCP
17