Table F‑1. Sensor head UPP commands (Continued)
Parameter
Command
Description
6 = 30 s
Valid values for IS 600, IGA 600, and IGA
600/23:
0 = Intrinsic time constant of the unit
(10 ms)
1 = 0.05 s
2 = 0.25 s
3 = 1 s
4 = 3 s
5 = 10 s
Emissivity
<AAXn>em<VAL>
Sets the emissivity of the sensor head
(percentage).
Valid values are 0100 to 1200 (10% to 120%).
Clear time
interval of the
maximum value
storage (t
cl
)
<AAXn>lz<VAL>
“l” is alpha.
Sets the clear time interval of the maximum
value storage of the sensor head.
Valid values are 0 to 8.
0 = Off
1 = 0.1 s
2 = 0.25 s
3 = 0.5 s
4 = 1 s
5 = 5 s
6 = 25 s
7 = External clearing
8 = Automatic clearing
External
clearing of the
maximum value
storage
<AAXn>lx<VAL>
“l” is alpha.
Simulates an external reset contact.
☞
Important
This command can only be used when
the clear time of the maximum value
storage (t
cl
) is set to 7 (external clearing).
Sensor head
address
<AAXn>sa<VAL>
Sets the sensor head address.
Valid values are 0 to 8 (0 = no address assigned).
Advanced Energy
®
Impac
®
Series 600 Pyrometer
57010228-00C
UPP Commands
F‑3