iLS600, iLS600-R and iLS1500 Series
Rev. 05.20.21_#1.0
advancedenergy.com
44
OUTPut:AUTOstart?
— This command returns the present configuration auto-start flag.
The returned value will be either ON or OFF.
OUTPut[:STATe] <ON|OFF>
— This command activates (ON) or deactivates (OFF) the unit
output.
OUTPut[:STATe]?
— This command returns the present output activation state, ON or OFF.
RSENse <ON|OFF>
— This command enables (ON) and disables (OFF) remote Remote
Sense mode. It must be executed with ON before any further remote sense commands can
be execution (except for queries).
RSENse?
— This command returns the present remote Remote Sense mode, ON or OFF.
RSENse:RESistance <ohms>
— Sets the remote sense resistance directly (as opposed to
running current through a lead and calculating it)
RSENse:RESistance?
— Returns the remote sense resistance in ohms.
RSENse:RESistance:CALCulate <current>
— This command initiates calculation of the
Remote Sense lead resistance at the specified load current. The current is specified in
amperes.
RSENse:RESistance:CALCulate?
— This command queries the Remote Sense calculation
status. The response is:
•
DORMANT – No calculation is active.
•
CALCULATING – A calculation is currently active.
•
COMPLETE – Most recent calculation is complete. This query returns the state to
Dormant.
APPENDIX