ELECTRICAL SYSTEM
FORM NO. 56043089 - AquaRide
™
-
65
SPECIAL PROGRAM OPTIONS (CONTINUED)
Restoring the scrub modes and pressures to factory default settings:
FACTORY DEFAULT: MODE = 0 (FIXED PRESSURE MODE), MAINTENANCE SCRUB PRESSURE = 3, RESTORE SCRUB PRESSURE = 8
If it is desired to restore the scrub switch operating mode and pressure limit to the default setting, perform the following steps:
1 Turn
the
main power key switch
to the
off
position.
2 Press and hold the
restore mode switch
.
3 While holding the restore mode switch turn the
main power key switch
to the
on
position.
4 Continue to hold the restore mode switch until the restore mode indicator is green.
5 Release the restore mode switch. The status display will now indicate “d” for done.
6 The scrub switch operating mode and pressure settings have now been restored.
7 Turn
the
main power key switch
to the
off
position.
Turning the Automatic Vacuum Shutoff Option On or Off:
FACTORY DEFAULT: ON
The AquaRide is equipped with a feature that will automatically shut off the vacuum and scrub systems and display “FULL” on the status display if
the recovery tank becomes
fi
lled. If problems are encountered with the vacuum automatic shutoff feature, such as the vacuum shutting off even
if the recovery tank is not full, this feature can be turned off (see also, vacuum auto-shutoff threshold adjustment). To turn this feature on or off
perform the following steps:
1 Turn
the
main power key switch
to the
off
position.
2 Press and hold the
vacuum switch
.
3 While holding the vacuum switch turn the
main power key switch
to the
on
position.
4 Continue to hold the vacuum switch until the vacuum indicator is green.
5 Release the vacuum switch. The status display will now indicate “E” or “d”.
6 Pressing and releasing the
vacuum
switch will now select between “E” for enabled or “d” for disabled. Enabled means that the automatic
shutoff feature is turned on, disabled means that the automatic shutoff feature is turned off.
7 To save the new setting, turn the
main power key switch
to the
off
position.
8 The new setting will be saved and will remain in effect until it is changed again.
Summary of Contents for 56314009
Page 1: ...5 03 revised 10 09 Form Number 56043089 AquaRide SERVICE MANUAL Advance MODEL 56314009...
Page 7: ...FORM NO 56043089 AquaRide 5 SPECIFICATIONS...
Page 25: ...WHEEL DRIVE SYSTEM FORM NO 56043089 AquaRide 23 A FRONT D F G E L J K I H N O Q P M R FIGURE 6...
Page 46: ...44 FORM NO 56043089 AquaRide RECOVERY SYSTEM FIGURE 3...
Page 49: ...RECOVERY SYSTEM FORM NO 56043089 AquaRide 47 FIGURE 5 FIGURE 6...
Page 55: ...ELECTRICAL SYSTEM FORM NO 56043089 AquaRide 53 FIGURE 4 FIGURE 3...
Page 72: ...70 FORM NO 56043089 AquaRide ELECTRICAL SYSTEM Drive Motor Breakdown...
Page 79: ......