SPECIAL PROGRAM OPTIONS (CONTINUED)
Vacuum Automatic Shut-off Threshold Adjustment:
FACTORY DEFAULT: 4
The sensitivity of the automatic vacuum shut-off feature can be adjusted if necessary. This adjustment sets the amount of change required in
the vacuum power consumption to cause the control unit to indicate a full recovery tank condition. The setting is adjustable from 0 to 9. 0 is the
minimum sensitivity, 9 is the maximum sensitivity. If the unit falsely indicates a tank full condition, try setting this parameter to a lower value. If the
control unit fails to shut the vacuum system off when the recovery tank
fl
oat ball plugs the vacuum inlet, try setting this parameter to a higher value.
To adjust the vacuum shut-off sensitivity perform the following steps:
1 Turn
the
main power key switch
to the
off
position.
2 Press and hold the
maintenance mode
and the
solution switch.
3 While holding both switches turn the
main power key switch
to the
on
position.
4 Continue to hold both switches until the solution indicator is
fl
ashing yellow.
5 Release both switches. The status display will now indicate a number from 0 to 9 depending on the threshold setting.
6 Pressing and releasing the
solution switch
will now select the threshold level. The level will increment from 0 to 9. 0 = minimum sensitivity, 9
= maximum sensitivity.
7 To save the new setting, turn the
main power key switch
to the
off
position.
8 The new setting will be saved and will remain in effect until it is changed again.
Recall Of Stored Error Codes:
Whenever an electrical system fault is detected by the main control unit, one or more error codes are displayed and stored by the control unit. If it
is desired, the error code (if any) from the previous operation of the machine can be recalled for troubleshooting purposes. To recall the last stored
error codes perform the following steps:
1 Turn
the
main power key switch
to the
off
position.
2 Press and hold the
solution switch
.
3 While holding the solution switch, turn the
main power key switch
to the
on
position.
4 Continue to hold the solution switch until the solution indicator is green.
5 Release the solution switch.
6 If there were previously no error codes stored, the display will now show “-”. Go to step 11.
7 If error codes were stored, the display will now show the stored code(s) and the scrub system off indicator will now be red. An example of how
two codes, 6 and 18, would be displayed is as follows:
•
The display will show “E” followed by a brief blank period
•
The display will show “0” followed by a brief blank period
•
The display will show “6” followed by a slightly longer blank period
•
The display will show “E” followed by a brief blank period
•
The display will show “1” followed by a brief blank period
•
The display will show “8” followed by a long blank period
•
The above sequence will repeat
8 To pause the display, press and hold the
solution
switch.
9 To clear the stored codes press and release the
scrub system off
switch. The display will now show “-“. Go to step 11.
10 If it is desired to save the codes, go to step 11.
11 To exit the error code recall mode, turn the
main power key switch
to the
off
position.
Summary of Contents for 56314009
Page 1: ...5 03 revised 10 09 Form Number 56043089 AquaRide SERVICE MANUAL Advance MODEL 56314009...
Page 7: ...FORM NO 56043089 AquaRide 5 SPECIFICATIONS...
Page 25: ...WHEEL DRIVE SYSTEM FORM NO 56043089 AquaRide 23 A FRONT D F G E L J K I H N O Q P M R FIGURE 6...
Page 46: ...44 FORM NO 56043089 AquaRide RECOVERY SYSTEM FIGURE 3...
Page 49: ...RECOVERY SYSTEM FORM NO 56043089 AquaRide 47 FIGURE 5 FIGURE 6...
Page 55: ...ELECTRICAL SYSTEM FORM NO 56043089 AquaRide 53 FIGURE 4 FIGURE 3...
Page 72: ...70 FORM NO 56043089 AquaRide ELECTRICAL SYSTEM Drive Motor Breakdown...
Page 79: ......