Chapter 2. Installation
32
TSU 600 User Manual
61200.076L2-1
Chain-out
This is used to connect to another TSU 600
Chain-in
connector. See Table 2-C for the pinout for the chain-
out connector.
Connections
The chain-out connections are as follows:
Connector type
RJ-48
Part number
AMP# 555164-2
Table 2-C
Chain-out Pinout
PIN
NAME
DESCRIPTION
1
GND
Ground - connected to unit chassis.
Connected to GND of next unit (pin 1).
2
UNUSED
3
TX DATA
Data transmitted to chained units by the
TSU 600. Connect to RX DATA of the next
unit (chain in pin 3).
4
UNUSED
5
RX DATA
Data received from chained units by the
TSU 600. Connect to TX DATA of the next
unit (chain in pin 5).
6,7,8
UNUSED