Chapter 3. Operation
54
TSU 600 User Manual
61200.076L2-1
SES
Number of severely errored seconds
(more than 320 errors/second)
UAS:
Number of unavailable seconds (10 or
more consecutive seconds)
If insufficient time has passed to collect data,
NA
is
displayed. Continue with standard operating proce-
dures to exit the display.
When this menu is active, performance data can be
cleared by pressing
Clear
(
shift 9
) on the keypad.
Only the user copy of the performance data is cleared.
Since only the user’s copy of performance data is cleared by
the TSU 600, the data displayed here might be different
from the data sent to the network as PRM data.
Network Interface Errors (NI ERRORS)
The NI Errors submenu is used to view the type of
errors detected by the Network Interface (NI). A
blinking CSU error LED indicates that network errors
are detected.
With the cursor on Main menu item 1)STATUS,
activate the menu with
Enter
or number
1
. The unit
displays the first two Status submenu items with the
cursor on
1)NI PERF RPTS.
With the arrows
or number
2
, select 2)NI ERRORS.
Activate the selection with
Enter
or number
2
. The
unit displays an asterisk (
*
) above an error type as in
Figure 3-10.
Summary of Contents for TSU 600
Page 1: ...61200 076L2 1B July 1997 TSU 600 USER MANUAL Part Number 1200076L2 1200076L2 DC...
Page 4: ...Table of Contents...
Page 96: ...Chapter 3 Operation 84 TSU 600 User Manual 61200 076L2 1...
Page 118: ...Chapter 4 Example Operations 106 TSU 600 User Manual 61200 076L2 1...
Page 126: ...Appendix C System Configuration Charts 114 TSU 600 User Manual 61200 076L2 1...
Page 128: ...Appendix D TSU 600 System Messages 116 TSU 600 User Manual 61200 076L1 1...