4
3.
Look for
Option 66
.
If Option 66
is not
already defined, select
Add
.
Name
UC
Server
Provisioning Server
Data Type
String
Code
66
Description
UC Server Provisioning Server IP Address
If Option 66
is
already defined:
If it is defined as a String type and the value is the IP address for the UC server,
no action is required.
If it is not defined as a String type and/or the value is not the IP address for the
UC server, automatic detection of the Mitel phones is not possible unless this
option can be changed as per the instructions above.
4.
Select
OK
.
5.
Right-click the
Scope Options
for the domain and select
Configure Options
.
6.
Select the check box next to
Option 66
.
7.
For the
String
field, enter the IP address of the UC server (for example, 123.45.67.89).
8.
Select
OK.
NOTE
: For DHCP servers other than Windows Server 2003/2008 and Windows SBS, consult the
appropriate documentation and fill in the options as indicated in Step 3.
Preparation
This section provides instructions on how to apply firmware upgrades (if necessary) and how to set up the
phone for automatic detection and provisioning.
Setting the Protocol
Mitel supports two protocols: MiNET and SIP. MiNET is a proprietary communication protocol
developed by Mitel exclusively for their private branch exchange (PBX) systems. Mitel phones by default
ship with the MiNET protocol enabled. Because the UC server uses SIP for communication, you must
change the phone to SIP mode.
To set the phone to SIP mode:
Hold down the
*
and
7
keys while the phone is booting. After about 5 seconds, a message will
appear on the screen that says
CHANGE CONFIRMED
. This means that the phone is now in
SIP mode.