background image

NetVanta 3100 Series Hardware Installation Guide

 FCC-Required Information

61700600L2-34C

Copyright © 2015 ADTRAN, Inc.

5

FCC-Required Information

FCC regulations require that the following information be provided in this manual:

1. This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and 

requirements adopted by America’s Carriers Telecommunications Association (ACTA). Each 
registered interface has a label that contains, among other information, a product identifier in the 
format US:AAAEQ##TXXXX. If requested, provide this information to the telephone company.

2. If this equipment causes harm to the telephone network, the telephone company may temporarily 

discontinue service. If possible, advance notification is given; otherwise, notification is given as 
soon as possible. The telephone company will advise the customer of the right to file a complaint 
with the FCC.

3. The telephone company may make changes in its facilities, equipment, operations, or procedures 

that could affect the proper operation of this equipment. Advance notification and the opportunity 
to maintain uninterrupted service are given. 

4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty 

information. The telephone company may require this equipment to be disconnected from the 
network until the problem is corrected, or it is certain the equipment is not malfunctioning.

5. This unit contains no user-serviceable parts.

6. This equipment is designed to connect to the telephone network or premises wiring using an 

FCC-compatible modular jack, which is compliant with Part 68 and requirements adopted by 
ACTA.

7. The following information may be required when applying to the local telephone company for 

leased line facilities:

8. The ringer equivalence number (REN) is useful in determining the quantity of devices you may 

connect to your telephone line and still have all of those devices ring when your number is called. 
In most areas, the sum of the RENs of all devices should not exceed five. To be certain of the 
number of devices you may connect to your line as determined by the REN, call your telephone 
company to determine the maximum REN for your calling area.

9. This equipment may not be used on coin service provided by the telephone company. Connection 

to party lines is subject to state tariffs. Contact your state public utility commission or corporation 
commission for information.

Part Number

Registration Number

Service Type

REN/SOC

FIC

USOC

1700600L2

US: HDCMM01A1700600L2

Analog Loop Start

0.1A/9.0Y

02LS2

RJ-11C

1700610L2

US: HDCDL01A1700610L2

ADSL, ADSL2, ADSL2+ Modem

0.1A

Metallic

RJ-11C

Summary of Contents for NetVanta 3140 Desktop

Page 1: ...nta 3130 Annex A with DBU 1700611G2 NetVanta 3130 Annex A with DBU 1700612G2 NetVanta 3130 Annex B without DBU 1700340F1 NetVanta 3140 Desktop 1700341F1 NetVanta 3140 1700508F1 19 inch Dual Mounting T...

Page 2: ...this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchase...

Page 3: ...2 34C Copyright 2015 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provi...

Page 4: ...ot dispose of batteries in a fire They may explode Check with local codes for special disposal instructions 5 The socket outlet shall be installed near the equipment and shall be easily accessible If...

Page 5: ...arranty information The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning 5 This unit...

Page 6: ...ion que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas cinq Canadian Emissions Requirements This digital apparatus does not exceed the Class A limits for radio noi...

Page 7: ...19 NetVanta 3140 Series 20 NetVanta 3140 Features and Specifications 20 NetVanta 3140 Shipping Contents 21 NetVanta 3140 Desktop Front Panel Design 21 NetVanta 3140 Desktop Rear Panel Design 22 NetVa...

Page 8: ...Table of Contents NetVanta 3100 Series Hardware Installation Guide 8 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Page 9: ...3130 with DBU Rear Panel Layout 19 Figure 8 NetVanta 3130 without DBU Rear Panel Layout 19 Figure 9 NetVanta 3140 Desktop Front Panel Layout 21 Figure 10 NetVanta 3140 Desktop Rear Panel Layout 22 Fig...

Page 10: ...List of Figures NetVanta 3100 Series Hardware Installation Guide 10 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Page 11: ...Panel LEDs 24 Table 2 NetVanta 3140 Series Front Panel LEDs 25 Table A 1 10 100Base T Ethernet Port Pinouts 37 Table A 2 1000Base T Gigabit Ethernet Port Pinouts NetVanta 3140 37 Table A 3 Console Po...

Page 12: ...List of Tables NetVanta 3100 Series Hardware Installation Guide 12 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Page 13: ...Installation on page 26 For additional information on mounting options and suppling power to the unit refer to the following sections Mounting Options on page 26 Supplying Power to the Unit on page 34...

Page 14: ...ted analog modem for dial backup or remote management 1700600L2 only ADTRAN Operating System AOS command line interface CLI User friendly web based graphical user interface GUI Standards based eBGP iB...

Page 15: ...m with the carrier and contact ADTRAN Customer Service refer to the Support page on the ADTRAN website at http www adtran com support Shipments of the NetVanta 3120 include the following items NetVant...

Page 16: ...ts The Ethernet port provides the following 10Base T or 100Base T with a single connector Auto negotiation CSMA CD IEEE 802 3 compatibility DBU Interface 1700600L2 only The NetVanta 3120 has a DBU por...

Page 17: ...p to 25 Mbps Some models include an integrated analog modem for dial backup and management IPsec VPN support is included without further software upgrade The unit is powered by a 12 VDC power supply A...

Page 18: ...deep penetration into the carton with sharp objects After unpacking the unit inspect it for possible shipping damage If the equipment has been damaged in transit immediately file a claim with the car...

Page 19: ...BU Interface 1700610L2 only The NetVanta 3130 has a DBU port on the rear panel to provide analog V 90 dial backup See Table A 4 on page 38 for the DBU connector pinouts Factory Default Switch The NetV...

Page 20: ...ure release IPsec VPN support is included with a further software upgrade NetVanta 3140 Features and Specifications The NetVanta 3140 offers the following features Three routed 10 100 1000Base T Ether...

Page 21: ...n into the carton with sharp objects After unpacking the unit inspect it for possible shipping damage If the equipment has been damaged in transit immediately file a claim with the carrier and contact...

Page 22: ...se Te 100Base T or 1000Base T via RJ 45 Auto negotiation CSMA CD IEEE 802 3 compatibility Auto MDIX USB Interface Future Release The USB interface is a type A USB host connector and is provided for us...

Page 23: ...hernet ports provide the following 10Base Te 100Base T or 1000Base T via RJ 45 Auto negotiation CSMA CD IEEE 802 3 compatibility Auto MDIX USB Interface Future Release The USB interface is a type A US...

Page 24: ...code could not be booted WAN NetVanta 3130 only Off The interface is administratively down Green solid The link is up and everything is operational Green flashing The port has activity Red solid An al...

Page 25: ...There is activity on the link Red solid An alarm condition is occurring on the USB port or there is a failure LINK GIG 1 GIG 3 1700340F1 only Off The port is administratively disabled or does not hav...

Page 26: ...be installed in a wallmount or tabletop configuration The NetVanta 3140 P N 1700341F1 can be mounted in a rack alone or with two units side by side using the optional dual mounting tray P N 1700508F1...

Page 27: ...ion 1 Decide on a location for the unit Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are viewable 2 Prepare the mounting surface by attaching a board typically...

Page 28: ...p left or right Figure 14 illustrates the unit mounted with the front panel facing to the left Keep in mind that the unit needs to be mounted at or above eye level so that the LEDs are viewable 3 Prep...

Page 29: ...NetVanta 3100 Series Hardware Installation Guide Unit Installation 61700600L2 34C Copyright 2015 ADTRAN Inc 29 Figure 14 NetVanta 3140 Single Wallmount Installation...

Page 30: ...eeds to be mounted at or above eye level so that the LEDs of both units are viewable 3 Prepare the mounting surface by attaching a board typically plywood 3 4 inch to 1 inch thick to a wall stud using...

Page 31: ...he equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer Installation of the equipment in a rack should be such that the amount of air flow required...

Page 32: ...screws shipped with the mounting brackets when attaching them to the chassis 2 To allow proper grounding scrape the paint from the rack around the mounting holes where the NetVanta will be positioned...

Page 33: ...he screws provided 2 To allow proper grounding scrape the paint from the rack around the mounting holes where the tray will be positioned 3 Position two NetVanta units side by side on the mounting tra...

Page 34: ...s Powering the NetVanta 3120 Series 3130 Series 3140 Desktop To power the NetVanta 3120 Series NetVanta 3130 Series and the NetVanta 3140 Desktop follow these instructions Figure 18 NetVanta 3100 Seri...

Page 35: ...of the unit Connect the other end of the power cord into a properly grounded AC power source Your NetVanta unit is now ready to be configured and connected to the network For information on configurat...

Page 36: ...Unit Installation NetVanta 3100 Series Hardware Installation Guide 36 Copyright 2015 ADTRAN Inc 61700600L2 34C...

Page 37: ...rail switch ports only 7 8 Unused Table A 2 1000Base T Gigabit Ethernet Port Pinouts NetVanta 3140 Pin Name Description 1 TRD0 Transmit Receive Positive 2 TRD0 Transmit Receive Negative 3 TRD1 Transm...

Page 38: ...lation Guide 38 Copyright 2015 ADTRAN Inc 61700600L2 34C Table A 4 DBU Connector Pinouts Pin Name Description 1 2 Unused 3 R Network Ring 4 T Network Tip 5 6 Unused Table A 5 ADSL Connector Pinouts Pi...

Reviews: