MX3216 System Manual
4-10
61189008L1-1B
INSTALLING CARDS AND MODULES
The MX3216 system is designed with hot-swappable controller cards and modules. This
section provides installation procedures for the different components of the MX3216 system.
•
•
“Installing the MX3216 Controller Card”
•
Installing the Fan Module
CAUTION
The MX3216 Controller Card requires that the MX3 Fan Module
(P/N 1189007L1) be installed in the MX3 chassis in sites where the
temperature can exceed 50°C. For applications with ambient tem-
peratures below 50°C, the MX3 Fan Module is not required. The
MX3 chassis with the fans installed is not intended to be deployed
in Central Offices or similar network facilities where the Telcordia
GR-63-CORE or ANSI T1.319-2002 shelf level burn test is
required.
The MX3 Fan Module mounts in the MX3 chassis (P/N 1189001L1). Follow the steps listed
below to install the MX3 Fan Module.
illustrates the installation of the MX3 Fan
Module.
1. With the screw oriented to the left, insert the MX3 Fan Module into the MX3 chassis until
the MX3 Fan Module is properly seated in the backplane.
2. Using a flat or phillips-head screwdriver, tighten the screw to secure the MX3 Fan Module
to the MX3 chassis.
Figure 4-7. MX3 Fan Module Installation
Summary of Contents for MX3216
Page 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Page 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Page 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Page 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Page 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...