Section 3, Application Guidelines - MX3216 Data Path Block Diagram
61189008L1-1B
3-3
Drop and Continue Application
In the drop and continue application, up to eight DS1s from one DS3 can be dropped out the
eight DSX-1 ports with the remaining DS1s continuing through to the other DS3 interface (see
). This allows one DS3 worth of bandwidth to deliver DS1s to several sites using one
MX3216 at each site.
Figure 3-2. Drop and Continue Application Diagram
shows the equipment needed for a drop and continue application.
Table 3-1. Drop and Continue Application - Required Equipment
Part #
Equipment
Quantity
1189001L1
MX3 Chassis
1
1189007L1
MX3 Fan Module
1
1189008L1
MX3216 Controller Card
1 (2 for redundancy)
MX3216
MX3216
DS3
Drop DS1s
to Local
Equipment
Original DS1s
continue
downstream;
AIS in
unmapped DS1s
Original DS1s
continue
downstream;
AIS in
Unmapped DS1s
Drop DS1s
to Local
Equipment
28 DS1s
from
Central Site
Central Site
Remote Site #1
Remote Site #2
DS3
µ Wave/
Leased
DS3
DS3
DS3
DS3
DS3
µ Wave/
Leased
DS3
AIS
AIS
Summary of Contents for MX3216
Page 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Page 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Page 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Page 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Page 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...