Section 2, Engineering Guidelines - Power Requirements
61189008L1-1B
2-3
POWER REQUIREMENTS
The following two sections detail the power requirements for the MX3216 Controller Card, the
MX3RMM, and the MX3216 system.
Module Configurations
provides the current draw of each module at –48 VDC (operating range of –42 VDC
to –60 VDC) and ±24 VDC (operating range of ±22 VDC to ±27 VDC).
System Configurations
provides the total current draw at –48 VDC and ±24 VDC for the different MX3216
system configurations.
Table 2-3. Maximum Current Draw
Part Number
Equipment
Maximum Current Draw
at –48 VDC
Maximum Current Draw
at ±24 VDC
1189004L1
MX3RMM
0.07 amps
0.15 amps
1189007L1
MX3 Fan Module
0.05 amps
0.10 amps
1189008L1
MX3216
0.30 amps
0.59 amps
1189008L1
MX3216 (redundant pair)
0.45 amps
0.90 amps
Table 2-4. Total Current Draw
Part Number
Quantity
Total Current Draw
at –48 VDC
Total Current Draw
at ±24 VDC
MX3216 (non-redundant) with one MX3RMM
1189004L1
1
0.34 amps
0.69 amps
1189007L1
1
1189008L1
1
MX3216 (redundant) with one MX3RMM
1189004L1
1
0.50 amps
1.00 amps
1189007L1
1
1189008L1
2
Summary of Contents for MX3216
Page 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Page 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Page 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Page 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Page 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...