![ADTRAN MX3216 System Manual Download Page 18](http://html1.mh-extra.com/html/adtran/mx3216/mx3216_system-manual_2854423018.webp)
MX3216 System Manual
1-4
61189008L1-1B
MX3216 Controller Card ACO Button
The alarm cut off (ACO) button disables any audible alarms. Any active visual alarms remain
active. Press the
ACO
button on the front panel to disable any audible alarms.
DSX-1 STAT
4
4
Off
Green
Red
Red (Flashing)
Red (Flashing once per event)
All DSX-1 drops are disabled
Enabled DSX-1 drops normal (All OK)
Non-critical alarm (AIS) on an enabled DSX-1
drop
LOS on an enabled drop
Single/Burst RX DSX-1 code violations during
previous second
DSX-1 TEST
4
4
Off
Red (Flashing once per event)
Amber
Amber (Flashing)
No DSX-1 tests in progress
Single/Burst pattern errors on drop in test
In test (locally originated)
In test (remotely originated)
Table 1-3. Standby MX3216 Controller Card LED Status
Label
Status
Description
ACT
4
4
Green
Amber
Amber (Flashing)
Red (Flashing)
Normal (All OK)
Software update in progress
Not ready or software mismatch
Card failure
ALM
Off
Permanent state during standby
DS3 A/B
Off
Permanent state during standby
DSX-1 STAT
Off
Permanent state during standby
DSX-1 TEST
Off
Permanent state during standby
Table 1-2. Active MX3216 Controller Card LED Status (Continued)
Label
Status
Description
Summary of Contents for MX3216
Page 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Page 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Page 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Page 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Page 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...