Step 3: Connect Ethernet 

The C424G ONU supports four, 1 Gigabit (10/100/1000Base-T) connections (1 to 4). 
If Ethernet cables are not available, use the following procedure and table to create the Ethernet cables:

1. Trim the insulation for the subscriber Ethernet cable.
2. Using a CAT 6 cable, connect the wires per the following table using an RJ-45 Crimper.

3. Refer to 

Figure 1

 and insert the CAT 6 rated cable in the appropriate Ethernet port.

Step 4: Connect Power

Refer to 

Figure 1

 and plug the 12 VDC Power Adapter (supplied with the unit) into the 

12V DC2.5A

 connection on the rear of the chassis. 

Connect the AC plug to a standard 120 VAC outlet.

Step 5: Connect Uninterrupted Power Source (UPS) 

The step is optional. The C424G ONU can typically use an un-interruptible power supply (UPS) if desired. Power is supplied to the 
C424G ONU by a local power source with battery backup that utilizes the AC power at the customer premises. The UPS powers the 
C424G ONU supplying continuous 12 VDC. Refer to the installation material that is provided with the UPS.
To connect UPS, refer to 

Figure 1

 and connect a UPS cable from the source to the UPS port on the rear of the unit.

g

     NOTE

ADTRAN offers a UPS Cable assembly (P/N 1287402G1) for this connector.

The UPS Power/Alarm Connections Table below defines each pin on the connector. 

UPS Power/Alarm Table

The following table below provides a pinout of the UPS connection.

If an UPS is being used and its internal battery is disconnected or fails, the C424G ONU is not protected from power outages, and will 
send a “Battery Missing” alarm to the OLT.

Ethernet RJ-45 Pin-out

Pin

Name

Description

Color Code

1

TRD0+

Transmit/Receive Positive

White/Orange

2

TRD0-

Transmit/Receive Negative

Orange

3

TRD1+

Transmit/Receive Positive

White/Green

4

TRD2+

Transmit/Receive Positive

Blue

5

TRD2-

Transmit/Receive Negative

White/Blue

6

TRD1-

Transmit/Receive Negative

Green

7

TRD3+

Transmit/Receive Positive

White/Brown

8

TRD3-

Transmit/Receive Negative

Brown

Pin-Out

Description

Alarm

1

Power Input (+12 VDC)

-

2

UPS Status - On Battery

1

3

UPS Status - Battery Missing

2

4

Signal Return

5

Power 12 V Return

-

6

UPS Status - Replace Battery

3

7

UPS Status - Low Battery

4

8

No Connection 

Summary of Contents for CenturyLink C424G

Page 1: ... and rear of the C424G ONU Figure 1 C424G ONU Front and Rear FEATURES The C424G ONU supports the following features Reset Button USB Four Ethernet Ports Two VoIP POTS Ports 2 4 GHz and 5 0 GHz WiFi 12 VDC Power Adapter USB Port 2 Front Rear 1 3 4 5 6 Item 1 Reset Item 2 USB Item 3 Ethernet Connections Item 4 VoIP POTS Connections Item 5 Power Item 6 UPS Item 7 WPS 7 FTTP C424G ONU 2P 4GE WIFI June...

Page 2: ...ttery charged WiFi The WiFi function allows you to connect wireless devices without entering a pre shared password key in the device WiFi supports the following protocols 802 11 b g n support on 2 4GHz radio with 2x2 MIMO antenna design 802 11 a n ac support on 5GHz radio with 4x4 MU MIMO antenna design g NOTE The pre shared password key is the default password and is located on the label of the C...

Page 3: ...ottom of the C424G ONU 2 Thread the fiber cable through the opening in the base If there is excess fiber carefully wrap it around the Fiber Tray Remove the plug from the SC APC Connector and insert the fiber cable Retain this plug and insert it in the fiber connection when the fiber cable is not connected This will protect the optical portion of the connection Wall Mount Installation To wall mount...

Page 4: ...er to the installation material that is provided with the UPS To connect UPS refer to Figure 1 and connect a UPS cable from the source to the UPS port on the rear of the unit g NOTE ADTRAN offers a UPS Cable assembly P N 1287402G1 for this connector The UPS Power Alarm Connections Table below defines each pin on the connector UPS Power Alarm Table The following table below provides a pinout of the...

Page 5: ...Link Connected Link Lost INTERNET PPP AUTO DETECTION Green Red During Auto Detection unit will alternate between Green and Red until unit is detected REGISTRATION ID Internet PPP and or IPOE LED during Registration ID will function as follows CONNECTION FAILURE Red Red indicates Auto Detection failed LED will remain Red for 5 seconds then Auto Detection will resume AUTHENTICATED W PPP CREDENTIALS ...

Page 6: ...UB LIC IP CONNECTION VERIFIED 4 Green Green Flashing Static IP verified and connected LAN to WAN and WAN to LAN connectivity in process ETHERNET 1 4 2 Off Green Green Flashing Fast Unit is not connected Link is up Data is being sent or received USB 2 Off Green Green Flashing Fast Power Off or no device connected Device connected Data is being sent or received WIFI 2 4GHZ WIFI ENABLED DISABLED 2 Of...

Page 7: ...pairs be attempted in the field Repair services may be obtained by returning the defective unit to ADTRAN Refer to the warranty for further infor mation Field support for software is provided through upgrade facilities VOIP 1 2 VOIP SIP REGISTRATION 2 2 Off Green Green Flashing Yellow Yellow Green Flashing Red VoIP Disabled in the Gateway VoIP Traffic Registered and Active VoIP Traffic is being tr...

Page 8: ...ILABILITY 1 800 827 0807 61287781F1C 13A Documentation for ADTRAN Network Solutions products is available for viewing and download directly from the ADTRAN Support Community website Go to https supportforums adtran com welcome Registration is required ADTRAN offers training courses on our products including customized training and courses taught at our facilities or at customer sites For inquiries...

Reviews: