61287781F1C-13A
7
S
PECIFICATIONS
■
Electrical
♦
Voltage: 12 Volts typical
♦
Minimum Voltage: 11.4 Volts
♦
Maximum Voltage: 12.6 Volts
♦
Power Consumption: Typical 21.0 watts
■
Physical
♦
9.88 inches high (25.1 centimeters)
♦
7.28 inches deep (18.5 centimeters)
♦
1.4 inches wide (3.8 centimeters)
♦
Weight: 1.17 pounds (0.53 kilograms)
■
Environmental
♦
Operational Temperature: 32°F to +104°F (0°C to +40°C)
♦
Storage Temperature: –4°F to 140°F (–20°C to +60°C)
♦
Relative Humidity: 90%, noncondensing
■
Optical
♦
TX min power: +0.5 dBm
♦
TX max power: +5.0 dBm
♦
RSSI max sensitivity: –27.0 dBm
♦
R.0X overload: –8.0 dBm
♦
TX wavelength: 1310 nm typical
♦
RX wavelength: 1490 nm typical
M
AINTENANCE
The C424G ONU does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be
attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the warranty for further infor-
mation. Field support for software is provided through upgrade facilities.
VOIP 1 - 2
VOIP/SIP
REGISTRATION
2
-
2
Off
Green
Green Flashing
Yellow
Yellow/Green
Flashing
Red
VoIP Disabled in the Gateway.
VoIP Traffic Registered and
Active.
VoIP Traffic is being transmitted.
VoIP Setup process failure.
Attempting to Register to Network.
VoIP Registration to Network
Failed.
WPS
WPS CONNECTION
STATUS ENABLED/
DISABLED
Off
Green
WPS Disabled.
WPS Enabled.
CONNECTION IN
PROGRESS
-
Yellow Flashing
Connection in process.
AUTHENTICATION
STARTED
-
2
Yellow/Green
Flashing
Authentication in process.
SESSION OVERLAP
DETECTED
4
Red Flashing
Session Overlap Detected. Blink-
ing will continue until Overlap is
cleared.
WPS SUCCESSFUL
2
Green
Green Flashing
WIPS Enabled.
WPS Session Initiated.
Label
Function
Status
Indication