Chapter 2. Technology Overview
61200263L1-1.1
ATLAS Frame Relay User Manual
2-7
56k. Although data could burst from site A to the frame relay network at the
full T1 speed of 1.536 Mbps, it would queue up in the frame relay network
until it could be sent across the 56-kbps DDS circuit. This queue could cause
network congestion.
Managing Network Congestion
If congestion becomes a problem within the network due to excessive data
being delivered from one of the sites, the frame relay switch attempts to flow
control the data by sending bits that notify network devices that transmis-
sions in the opposite direction are congested. These bits are called Backward
Explicit Congestion Notification (BECN) and Forward Explicit Congestion
Notification (FECN).
For example, if a frame relay switch begins to experience congestion, it sends
the upstream site a FECN and the downstream site a BECN. This notification
indicates to the frame relay equipment that the frame relay switch is experi-
encing difficulty and that the frame relay device should begin to flow control
its traffic.
Figure 2-4 shows an example of FECN and BECN messages being transmit-
ted to the frame relay equipment when congestion occurs. Both ends are no-
tified that congestion is occurring within the switch. You might wonder why
the receiving end should receive notification of congestion and then flow
control its data when the other end is causing the problem by sending large
amounts of data. Flow control is used by the receiving end so that upper lay-
er acknowledgments from the destination slow down, thereby reducing the
amount of data being transmitted from the source.
Figure 2-4. Network Congestion and Flow Control
This overview is not intended to be all inclusive of the operation of
a frame relay network. It is intended to help simplify the frame
relay configuration within ATLAS.
BECN
Data Source
Frame Relay/
Router
Frame Relay/Router
Switch Congestion
FE
C
N
Frame Relay/Router
Frame
Switch
Frame
Switch
Data Destination
Summary of Contents for ATLAS
Page 1: ...ATLAS Frame Relay User Manual Part Number 1200263L1 1 61200263L1 1 1D May 2000...
Page 10: ...List of Figures x ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 12: ...List of Tables xii ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 16: ...Chapter 1 Introducing ATLAS Frame Relay 1 4 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 28: ...Chapter 3 Enabling Frame Relay 3 4 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 52: ...Chapter 4 Defining Packet Endpoints 4 24 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 82: ...Chapter 6 Frame Relay Configuration Examples 6 22 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 90: ...Chapter 7 Using Frame Relay IQ 7 8 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 104: ...Index Index 6 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 106: ......