61200263L1-1.1
ATLAS Frame Relay User Manual
A-1
Appendix A
Troubleshooting
Frame relay link is down.
Potential Cause
Solution
Cabling problem
T1
1. Check the ports’ alarm status.
2. If the T1 is experiencing LOS, ensure the cable is plugged in.
3. If the cable is plugged in, ensure the pinout is correct. Refer to
the
ATLAS User Manual for a correct pinout.
Nx
1. Check DTE port signals and verify that DTR and RTS are active.
2. If signals are inactive, verify V.35 cable is connected to correct
port.
3. If cable is connected, verify external DTE is powered on.
Packet endpoint not mapped
From P
ACKET
M
ANAGER
/P
ACKET
E
NDPNTS
/S
TATUS
, verify that the
packet endpoint indicates that a physical port is mapped.
Signaling mismatch
From P
ACKET
M
ANAGER
, verify that the Signaling type matches that
provided by the carrier and the external DTE.
Timers not configured
Verify that frame relay counters and timers are configured as
specified by the frame relay provider. (Counters and timers do not
normally need to be adjusted.)
Summary of Contents for ATLAS
Page 1: ...ATLAS Frame Relay User Manual Part Number 1200263L1 1 61200263L1 1 1D May 2000...
Page 10: ...List of Figures x ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 12: ...List of Tables xii ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 16: ...Chapter 1 Introducing ATLAS Frame Relay 1 4 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 28: ...Chapter 3 Enabling Frame Relay 3 4 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 52: ...Chapter 4 Defining Packet Endpoints 4 24 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 82: ...Chapter 6 Frame Relay Configuration Examples 6 22 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 90: ...Chapter 7 Using Frame Relay IQ 7 8 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 104: ...Index Index 6 ATLAS Frame Relay User Manual 61200263L1 1 1...
Page 106: ......