Installation
61287802F1-34B
35
Revision B
3. Remove the Power/Alarm Connector from the Electronics Module by pulling it directly
from the module (see
).
Figure 12. Power/Alarm Connector Pinouts
NOTE
g
For replacement pinouts or cables, please see
Section 4.1.1, “Replacement Parts and Acces
4. Route the wires through the rubber grommet for the power/alarm connector (see
).
Figure 13. Power/Alarm Connector Wire Routing
Table 7. Power/Alarm Connector Pinouts
Pin
Description
1
Low Battery
2
Battery Missing
3
Replace Battery
4
On Battery
5
Signal Return
6
12V Return
7
+12 VDC
234567
1
Power/Alarm Connector
Pin 1
Pin 7
Fiber Connection
Ground Connection
Power Connection
Bulkhead Connector