Chapter 5. Configuration Menu
44
ESU LT User Manual
61200410L2-1A
RFA Gen
When enabled, remote frame alarm is transmitted toward the
network during alarm.
Choices:
E
NABLE
;
D
ISABLE
Timing Mode
Selects the clock source for transmission toward the network from
the NI.
Choices:
N
ETWORK
;
I
NTERNAL
;
DTE
Network Timing
The network is the source of timing. The received data clocking is
looped back to the network, where it is used to determine the
transmission timing. This option is also referred to as looped timed
as the transmission clock is derived from the received clock. See
Figure 5-2.
Figure 5-2. Network Timed Clock Source
The clocking option selected always designates the clock source
for transmission. Clocking necessary for receiving data is always
recovered from incoming data.