49
QS2 Series Low Voltage Servo Drive
No. Parameter name
Function
Range
P38
Internal speed 4 The set speed is 4 when operating in a internal 4-stage
speed control mode;
0
-
5000
P39
Internal
position 1
The set speed is 1 when operating in an internal 4-
stage speed control mode;
0
-
±32000
P40
Internal
position 2
The set position is 2 when operating in an internal 4-
stage position control mode;
0
-
±32000
P41
Internal
position 3
The set position is 3 when operating in an internal 4-
stage position control mode;
0
-
±32000
P42
Internal
position 4
The set position is 4 when operating in an internal 4-
stage position control mode;
0
-
±32000
P43 Correspondence
address
1
0
-
255
P44
Communication
baud rate
0--4800,1-9600,2-14400,3-19200,4,5-38400,6-57600,
7-115200;
0
-
7
P45
Torque arrival
percentage
Set the proportion between the set analog quantity
torque input voltage and the actual motor
operating torque;
Unit of the setting value is 0.1V/100%;
Default value is 100 with 10V/100%
,
which means
inputting 10V voltage will generate 100% rated
torque;
0
-
100
P46
Percentage of
motor static
torque
The torque of shaft locking when motor stops;
The unit of setting value is when the position loop is
valid , the speed loop and torque loop are invalid; the
set unit: the rated torque×100%;
0
-
disable this function;
Other values—this function available
0
-
100
P47
Open delay of the
electromagneti
c brake
Reservation function not available for now
0
-
32000