QS2 Series Low Voltage Servo Drive
No. Parameter name
Function
Range
P57
Rated torque
Only the motor model set as (P2=9999) can the
parameter be valid;
The setting value means the rated torque of the motor,
only affecting the torque protection function of the
motor but not the operation of the motor;
Unit (0.1NM)
0-200
P58
Second
electronic gear
ratio numerator
Usage same as the first electronic gear ratio;
0
-
500
P59
Second electronic
gear ratio
denominator
Usage same as the first electronic gear ratio;
0
-
500
P60
Filtering
coefficient
Used to motor noise when the speed loop gain is too
large;
0—9
P61
Drive current
type
Reserved
P62
V phase current
zero-point
rectification
value
It means the float value of V phase current zero-point.
2008
-
2088
P63
W phase
current zero-
point
rectification
value
相电流
零
点校正值
It means the float value of W phase current zero-
point.
2008
-
2076
It is recommended to set and modify all parameters when the motor is stationary;
Before long-term storage, the parameters must be solidified and written;
When the drive power is cut off, wait at least 30 seconds before powering up again;
When the drive is used in numerical control system, the parameter P12 and P13 shall be
calculated as follows:
P
12
Mechanical deceleration ratio
System pulse equivalency
10000
P
13 Lead screw pitch (mm)
The pulse equivalency of general numerical control system is 0.001mm.