a)
Wipe after dispensing: Automatically start wipingwhen the dispensingis finished
b)
Wipingposition: The initial position of wiping(cleaning)
c)
Wipingstart input signal: Corresponding input signal configuration of external start and
PLC start
d)
Wipingend input signal: Input signal of custom wipingend
e)
Wipingrunning status output signal: Output signal of wipingrunning
f)
Wipingin-place output signal: Output port to wipingposition [configure this port to
determine the wiping mode used; initial setting is -1; if the port is configured, the
custom wipingmodeis used]
g)
Auto wipinginterval times: The times of processing before the wipingis performed
automatically [0 indicate that the process will not automatically trigger wiping]
h)
Number of wipingactions: The times of action repeatedin XY directionwhen wiping
i)
Wiping in-place output time: Response time when customizing wiping
j)
Wiping movement distance in X direction: X movement distance when wiping
k)
Wiping movement distance inY direction: Y movement distance when wiping
l)
Wiping speed: Speed of XY movement when wiping
m)
Start wiping: Trigger wiping actionon the hand-held box, used for debugging
Summary of Contents for DJ1600V1-A01
Page 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Page 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Page 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Page 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Page 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...