User Manual of TV5600-B01 Series Dispensing Control System
31
half doesn’t (like a cam).
Reset direction: If the coordinates increase when motor approaches to the origin, the reset
direction is positive, or else it is negative. Before setting this parameter, please make sure
that the moving direction of the motor after the direction key of the hand-held box motor is
pressed is the same as the direction indicated by the motor direction key on the hand-held
box. See the description of the handheld box keys for the positive and negative direction
keys of each axis button on the handheld box.
Reset high speed: The motor and speed approach to the origin.
Reset low speed: After approaching the origin, capture the origin signal at this speed.
Reset acceleration: The speed of the motor fromreset high speed to reset low speed. Use
the default value.
※
Note: If the number of axes used by the dispenser is less than the inherent number of axes of
the controller, simply set the “Reset mode” of the “Motor feature” parameter of the unused axis
to “no reset”.
After wiring and installation, the first step is to reset the dispenser. To complete the reset
function, you need to complete the relevant settings. Below is a brief description of the reset
settings:
The reset settings are configured in [System Settings] -> [Factory parameters] -> [Motor Features].
You can switch and set the parameters of different axes by pressing [F1] - [F6].
5.01 Pulse transmission mode setting
Main interface of the handheld box: When the manual button
of the handheld
box motor is pressed to move the positive direction of the mechanical structure, check whether
the real-time coordinate change of the main interface of the handheld box meets the
requirements (real-time coordinates from 0 to negative or from 0 to positive), if not, change to
pulse transmission mode (pulse & di is in the same group as pulse & direction-; pulse &
pulse+ is in the same group as pulse & pulse-). If the direction of the manual key of the hand-held
box motor is opposite to the actual direction, change [Whethersameas the direction of Cartesian
Summary of Contents for DJ1600V1-A01
Page 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Page 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Page 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Page 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Page 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...