APPLICATION HINTS FOR THE AUXILIARY TERMINALS
The Key Active Output switches to (-) ground for 10
seconds whenever a key is touched. You may use
it to turn ON an LED lamp and /or a small buzzer to
notify a guard; or to energize a relay to switch ON
lights or trigger an CCTV Camera to start recording.
Make sure that the relay for switching ON lights
has high enough isolation between high voltage
and low voltage to prevent damage of the keypad.
Only one connection option is recommended. Make
sure the sink current does not exceed the maximum
rating of 100mA.
External power supply and isolation relay are strictly
necessary in driving high power device, such as
lights.
The tamper switch is Normally Closed while the keypad
is secured on gang box. It is open when the keypad
is removed from the gang box. To prevent sabotage,
connect these terminals in series with a 24 hour N.C.
protection zone of an alarm system if required.
With the help of a Normally Closed door
position sensor (usually a magnetic door
switch) on the door to set up the following
functions:
Door Auto Relock
-- The system will immediately
relock the door after a valid access has been gained to
prevent "tailgate" entries.
Door Forced-open Alarm
-- The keypad will generate
alarm instantly if the door is forced to open. Enable the
function at Location 80.
Door Propped-up Alarm
-- The keypad will generate
alarm if the door is left open longer than the pre-set
delay time. Enable the function at Location 81.
Inter-lock Control
-- When the door is open, the
interlock output of the keypad will give a (-) command
to stop the other keypad in an inter-lock system.
a)
b)
c)
d)
(A) TAMPER N.C.
(B) DOOR SENS
(C) KEY ACTIVE -- SET THE "K OR A" JUMPER TO "K"
(a)
(b)
40
SPECIFICATIONS
Operating Voltage:
12V-24V AC/DC, No jumper selection is required for the full voltage range
Operating Current:
65mA (quiescent) to 100mA (three relays active)
Environmental Temperature:
-30
C to +70
C
Environmental Humidity:
5-95% relative humidity non-condensing
Working Environment:
All weather, IP-66
Number of Users:
Output 1 – 1,000 (PIN and/or Cards) + 50 Duress Codes
Output 2 – 100 (PIN and/or Cards) + 10 Duress Codes
Output 3 – 100 (PIN and/or Cards) + 10 Duress Codes
Proximity Card:
Standard EM Card or Keyfob, 125Khz
Number of Visitor Codes:
50, for Output 1 only (programmable for one time or with the time limited)
Timings for Code Entry and Card Reading:
10 seconds waiting for next digit entry
30 seconds waiting for code entry after card reading
The Timers:
Three 1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1, 2 & 3
Egress Button:
Programmable for Instant, Delay with Warning and/or Alarm
Momentary or Holding Contact for the Exit Delay
Input Sensing Terminals:
a)
Door position,
b)
Egress,
c)
O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a)
Duress,
b)
Alarm,
c)
Key Active,
d)
Output 3 (Door Bell version only),
e)
Inter-lock
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Output Relay 3 – N.C. & N.O. dry contacts, 1A/24VDC Max. (N.O. contact only for Door Bell version)
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
DK-2882A / DK-2882B – 156(H) X 103(W) X 50/70(D)mm
DK-2882C / DK-2882D – 151(H) X 97.5(W) X 42(D)mm
Weight:
DK-2882A / DK-2882B – 1.03Kg net
DK-2882C / DK-2882D – 460g net
Housing:
DK-2882A / DK-2882B – Anodized steel, powder paint coating outer box & plastic inner box
DK-2882C / DK-2882D – Plastic back box
Faceplate Material:
1.5mm stainless steel
Specifications are subject to change for modification without notice