FEATURE PROGRAMMING & OPERATION INSTRUCTIONS
SET SYSTEM IN PROGRAMMING MODE WITH THE MASTER CODE
IMPORTANT NOTE:
1) It is always necessary to set system in programming mode before the programming.
2) For the owner’s convenience in programming at the first time, the factory has put a Master Code
0 0 0 0
into the
keypad (
It is NOT a default code
). To compromise security, in all cases, the owner should program a new Personal
Master Code to invalidate the factory set Master Code after the keypad is owned.
3) The
Button
has two functions in the keypads with Door Bell button. It is a door bell button while the keypad is in
normal operation; and it is equivalent to a
*
Button
in programming mode.
MASTER CODE
The Master Code can be a factory set master code or the private master code that
was set by the owner.
Validate the master code with
* *
(or ) .
2-beep confirms a valid master code. The Mains LED (Amber) is constantly ON after the system is set in the
programming mode.
DIRECT ACCESS TO PROGRAMMING MODE WITH THE “DAP” CODE – 8 0 8 0
Set System To Programming Mode In Case Of The Master Code Is Forgotten ! !
The owner requires to apply the following procedures precisely to set the system into programming mode
with the DAP code
8 0 8 0.
1) Switch OFF all the power for 1 minute to ensure that the system is fully discharged.
2) Switch ON power again. The system is in Power-up Mode for 1 minute and the buzzer gives beeps during the whole
period. This is the only time limit the system to accept the DAP code
8 0 8 0
.
3) After keying in the DAP code and validate it with the
* *
(or ), the power up beep stops. The keypad turns
itself to programming mode like using the Master Code and it is ready to accept the new programming data.
4) If the DAP code is not keyed in within the power up period, the system will set itself to normal operation mode. To set
it back to power-up mode, repeat procedures 1-3.
DAP CODE
The DAP code is fixed on
8 0 8 0
and it is valid only in the Power-up Period.
Validate the DAP code with the
* *
(or )
.
2-beep confirms the system is in the Programming Mode; and the Mains LED is constantly ON.
See “RECORD A MASTER CODE” at “Location 01” for the details of programming a new master code.
NOTE:
If the keypad is linking up with the DA-2800 controller in the Split-decoded operation, it is necessary to put the
controller’s “Link-up Jumper” to “ON” position to get the new Master Code for it. As the Master Code is also the link-up
code of the two units.
Do Not Forget
to put the Link-up jumper back to OFF position after the programming. Otherwise,
the controller will accept other keypads to link up with it.
0000
8080
**
**
MASTER CODE
VALIDATION
DAP CODE
VALIDATION
.
.
.
.
.
.
.
10
PROGRAMMING SUMMARY CHART
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code
4-8 Digits
01
MASTER CODE
#
NIL
0 2
Super User PIN
4-8 Digits
02
SUPER USER PIN
#
NIL
0 3
Common User PIN for O/P 1
4-8 Digits
03
COMMON USER PIN 1
#
NIL
0 4
Common User PIN for O/P 2
04
COMMON USER PIN 2
#
NIL
0 5
Common User PIN for O/P 3
05
COMMON USER PIN 3
#
NIL
1 0
User PINs / Cards for O/P 1
CODE 1 - MEDIA:
1---EM Card
2---Private User PIN
3---EM Card+Sec User PIN
4---EM Card+Com User PIN
5---Detection of User
CODE 2 - USER ID:
000-999---Group 1(10)
001-100---Group 2(20)
001-100---Group 3(30)
CODE 3 - USER PINs / Cards:
4-8 Digits / Cards
10
CODE1
CODE2
CODE3
#
NIL
2 0
User PINs / Cards for O/P 2
20
CODE1
CODE2
CODE3
#
NIL
3 0
User PINs / Cards for O/P 3
30
CODE1
CODE2
CODE3
#
NIL
4 0
Visitor Codes
CODE 1 - VISTOR ID:
01-50
CODE 2 - VALID PERIOD:
00---One Time
01-99 Hours
CODE 3 - VISTOR CODE:
4-8 Digits
40
CODE1
CODE2
CODE3
#
NIL
4 1
Duress Code for O/P 1
CODE ID:
01-50
DURESS CODE:
4-8 Digits
41
CODE ID
DURESS CODE
#
NIL
4 2
Duress Code for O/P 2
42
CODE ID
DURESS CODE
#
NIL
4 3
Duress Code for O/P 3
43
CODE ID
DURESS CODE
#
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds,
Momentary
51
O/P MODE & TIME
#
5 Second
5 2
O/P Mode for O/P 2
52
O/P MODE & TIME
#
5 Second
5 3
O/P Mode for O/P 3
53
O/P MODE & TIME
#
5 Second
6 0
Personal Safety & Lock-out
LOCK-OUT CODE:
1---10 Trial, Lock-out 30 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Out 15
Minutes
00---No Lock-out
60
LOCK-OUT CODE
#
Code = 1,
10 Trials,
Lock-out 30
Seconds
7 0
PIN Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
70
ENTRY MODE
#
Mode = 2,
Manual Mode
7 1
Pacifier Tone ON-OFF
FUNCTION MODE:
0---OFF
1---ON
71
FUNCTION MODE
#
Mode = 1,
Pacifier Tone
ON
7 2
Output Announcer
72
FUNCTION MODE
#
Mode = 1
Announcer ON
7 3
Standby LED Flashing
73
FUNCTION MODE
#
Mode = 1,
Flashing On
35