VMT6010/6012/6015
12
© ads-
tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen
4 Commissioning
The power supply connection and interfaces of this device are installed underneath a protective cover.
This cover has to be removed in order to connect the power supply lead and the interface cables.
All supply leads and all required data leads have to be connected before commissioning. All supply
leads and all required data leads have to be connected before commissioning.
Warning:
The device must be switched off before connecting or disconnecting any cables in
order to prevent damage to the electronics!
The device may only be switched on after acclimatising to the ambient temperature
in order to avoid condensate accumulation. Make sure to meet the permissible
voltage requirements for this device.
After switching off and before switching on you must wait for at least 5 seconds.
Note:
The screen of a data cable must always be connected with the connector housing
(EMC).
Under the embedded operating system, interfaces must explicitly be enabled
and required drivers must be installed in order to be able to use them.
4.1 Available Interfaces
Abb. 4: