Zündungsfunktion (Ignition) 

The device is capable of being externally started by using an additional signal input. This function is well 
known from the automotive industry (switch-on by using an ignition contact). The device is here 
continuously supplied with a 24 V DC power supply, and only if the additional signal is present at the 
ignition contact, e.g. as a result of turning the ignition key of the forklift, the computer is switched on or 
the blocking is released. This function protects the system from unauthorised use, and saves energy by 
using the battery of the vehicle only in connection with the vehicle being used, at the same time, if the 
device is installed onboard of vehicles or other mobile and battery driven equipment. This function can 
be configured by using the Ignition Key Locking software tool. It allows you, for instance, to shut down 
the computer after expiry of a timer once the voltage is no longer present at the ignition contact. 

Preassembled supply cables that allow the use of this ignition function are available from ads-tec. 

 

Note: 

Switching the device ON or OFF by using the Power button will override the 
ignition function. That means, if the device is switched off by using the Power 
button, the system is shut down and can be restarted by using the Power 
switch after that, but can then also be restarted by using the ON/OFF 
function of the ignition.

 

 

 

Warning: 

The ignition signal works with a threshold value of 5V DC. The voltage must never 
exceed the maximum voltage of 36 V DC! Risk of destruction! 

Do not use the device onboard of vehicles with more than 24 V DC system voltage 
without any voltage adaptation for the ignition contact! Risk of destruction! 

 

 

Note: 

The ignition function must never be used together with the autostart function, 
at the same time!

 

 

 

Note: 

The ignition function is available with most operating systems.

 

 

Pos :  27 /D atent ec hni k/Schnitts tell en/Aut ost art/ Aut ost art f ür  VMT  60xx @  1 \ mod_1246631044840_6. doc  @  5885 @    

 

6.3  Autostart (S1) 

The autostart function allows the automatic start-up of the device upon application of the supply voltage 
of 24 V DC. 

 

Note: 

The Autostart switch in the service slot must be set to ON in order to use this 
function.

 

Pos :  28 /D atent ec hni k/Schnitts tell en/Lauts prec her/Lauts prec her f ür VMT  60xx @  1\ mod_1228482989111_6. doc  @  4247  @   

 

 

 

Summary of Contents for VMT6010

Page 1: ...User Manual Terminals VMT6010 6012 6015 Version 2 0...

Page 2: ...Damage Caused By Improper Use 8 2 3 Warranty Repair 8 2 4 Treatment and Disposal of Lithium Batteries 8 2 5 Notes on Safety 8 3 Mounting 9 3 1 External Device Dimensions VMT6010 9 3 2 External Device...

Page 3: ...9 Serial COM Interface RS232 31 7 Drives 32 8 Software Driver Installation 33 8 1 Configuration Center 35 8 1 1 Automatic Brightness Adaption 36 8 1 2 COM Input Configuration 37 8 1 3 Ignition 37 8 1...

Page 4: ...all currently applicable legal requirements and regulations The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical inn...

Page 5: ...erminate any warranty for this device Ads tec cannot be held liable for any damages arising due to improper use and handling Temperature for devices without a heater in operation 20 55 C for storage 3...

Page 6: ...pliance with the EMC legislation For this reason screened bus and LAN cables including screened connectors must be used and installed according to the instructions in this user manual Note By using th...

Page 7: ...y Please check that all of the following components are contained in the packaging Scope of Delivery VMT6000 series 1 x device 4 pin Lead through connector from Phoenix Contact COMBICON MC 1 5 4 STF3...

Page 8: ...e most important instructions on how to use this device in a safe way Appropriate storage proper transport installation and commissioning as well as careful operation are prerequisites for ensuring sa...

Page 9: ...exposed to higher temperatures the faster it ages Warning There is an acute risk of explosion should the wrong type of battery be used Warning Do not put lithium batteries into a fire do not solder on...

Page 10: ...VMT6010 6012 6015 9 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 Mounting 3 1 External Device Dimensions VMT6010 Abb 1...

Page 11: ...VMT6010 6012 6015 10 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 2 External Device Dimensions VMT6012 Abb 2...

Page 12: ...VMT6010 6012 6015 11 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 3 3 External Device Dimensions VMT6015 Abb 3...

Page 13: ...ng The device must be switched off before connecting or disconnecting any cables in order to prevent damage to the electronics The device may only be switched on after acclimatising to the ambient tem...

Page 14: ...ation Pos 18 D atentechni k Inbetri ebnahme R eihenfolg e der Inbetriebnahme R ei henfolge der Inbetriebnahme f r VMT 60xx Seri e 1 mod_1222073159179_6 doc 4100 4 2 Order of Steps during Commissioning...

Page 15: ...bsbereitschaft pr fen f r OPC C PC PLC OTC ITC VMT Serie Monitore IPC 5100 5500 2400 1100 0 mod_1158905578361_6 doc 381 4 3 Check for operational Readiness Check the device for any hidden damage poten...

Page 16: ...front panel are pre allocated with the following functions by a specific driver in the soft keyboard Level 1 Activate and deactivate the soft keyboard for letter character input by using the touch sc...

Page 17: ...d with an operating system Windows CE 6 0 Windows XP embedded or Windows XP Professional ex works and a soft keyboard is installed The keys on the front panel are pre allocated with the following func...

Page 18: ...rdance with customer specific requirements The above described functions are pre set ex works Pos 21 D atentechni k Bedienung Softkeyboard Softkeyboar d f r VM T 60xx 1 mod_1228750145198_6 doc 4251 5...

Page 19: ...first Due to differences in programming of a large variety of software programmes we cannot ensure that the soft keyboard works properly with all available software When deactivating the soft keyboar...

Page 20: ...ystem LED Indicators Behaviour Description static Device is connected with a power source and switched on flashing Volume display brightness is being modified static Minimum maximum value for volume d...

Page 21: ...able for automatic system login The user applies the RFID tag like a key and requires neither user name nor password For authentication the key card or the RFID chip are held in front of the position...

Page 22: ...epending on the hardware configuration a MIFARE or LEGIC RFID reader is installed MIFARE 1 To test the RFID function select the application ads tec RFID sample application on the pre installed Configu...

Page 23: ...12 If no RFID reader is found you have the opportunity to select the serial port to which the RFID reader is connected manually Abb 13 After selection of the COM port the application opens the por whi...

Page 24: ...of an RFID reader or a bar code scanner arrive automatically without the active application Abb 14 The functionality of the application can be integrated via the Configuration Center surface at any t...

Page 25: ...igure shows the socket inside the device Pin Number Signal Name 1 PE 2 0V DC 3 Ignition contact 4 24V DC Voltage tolerance Input voltage 24 V DC 20 Current consumption The current consumption of this...

Page 26: ...ectrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have...

Page 27: ...nition function are available from ads tec Note Switching the device ON or OFF by using the Power button will override the ignition function That means if the device is switched off by using the Power...

Page 28: ...volume can be set up by using the device front keys When activating the described key combinations the volume level is modified If the soft keyboard is installed the system volume is additionally disp...

Page 29: ...ces can be individually locked by using the Lock USB software tool USB Interface in Front panel One USB interface can be accessed from the front The interface is located under a plastic cover undernea...

Page 30: ...tzwer kanschluss RJ45 f r VMT60xx 2 mod_1260451135970_6 doc 6856 6 7 Netzwork Connection RJ45 If the drivers required for functioning are installed on the device the control system may be integrated i...

Page 31: ...eshared key WPA enterprise EAP TLS Specifications of this network topology must be observed in this case Note As an option this device can be equipped with an internal antenna and an external antenna...

Page 32: ...by using a commercially available 9 pin SUB D cable Note Pin 9 of the serial interface connector can be used for additional switching of a 5V power supply e g for operating a serial barcode scanner Th...

Page 33: ...ofessional Pos 35 D atentechni k Laufwer ke Exter ne Laufwerke Exter ne Laufwer ke f r OPC 5112 5115 5117 IPC 1100 CPC PLC OTC ITC VMT Serie 0 mod_1158926656205_6 doc 563 Externe Laufwerke By default...

Page 34: ...g one of the existing interfaces An external keyboard is required for installation Installation of the Operating System The device does not have any integrated CD drive The installation of the operati...

Page 35: ...TouchScreen folder Follow the on screen instructions and acknowledge the licence terms and conditions Once the installer has completed the installation shut down the computer and restart it subsequent...

Page 36: ...ads tec applications are installed on the device Additionally you can start any of these applications from the Configuration Center by double clicking on it Information In the Information section devi...

Page 37: ...both modes Note The threshold for Day Night mode has to be determined individually by the user for each device The day mode is enabled as soon as the ambient brightness is high enough The display bri...

Page 38: ...ication that uses the COM2 port forwarded Note Unnecessary applications that use the COM2 port must be stopped before running the COM input configuration Because of different programming data on vario...

Page 39: ...output in the event that a USB port is locked or not Additionally the locking process can be logged in the event log Password Protection In order to avoid any unauthorised access to the USB Lock prog...

Page 40: ...button configuration allows to change the behaviour of the ON OFF pushbutton Regular Mode The ON OFF pushbutton switched the device on and off Secure Mode The ON OFF pushbutton only switches the devic...

Page 41: ...order to test the function of the RFID reader Note In the Interfaces section of the manual you can find more information about the topic of RFIDs 8 1 7 Softkeyboard Here you can configure the soft key...

Page 42: ...st be installed from the enclosed service CD in order to ensure usability of the 5 keys except for the VMT series where you have 6 keys underneath the monitor The installation has to be carried out as...

Page 43: ...Flash SSD via internal USB connections 1 x Flash SSD via internal USB connections 1 2 x Flash SSD via internal USB connections 2 Alternativ 2 5 Automotive Hard Disk with min 40 GB SATA 2 5 Industrial...

Page 44: ...ly be answered by the system manufacturer For devices not directly purchased from ads tec we don t deliver any support The support is delivered by our associate companies in these cases 10 1 ads tec S...

Page 45: ...VMT6010 6012 6015 44 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen 11 Declaration of CE Conformity VMT6008...

Page 46: ...VMT6010 6012 6015 45 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6010 Glossar...

Page 47: ...VMT6010 6012 6015 46 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6012...

Page 48: ...VMT6010 6012 6015 47 ads tec GmbH Heinrich Hertz Str 1 D 72622 N rtingen VMT6015 Glossar Glossar...

Reviews: