VMT6010/6012/6015
24
© ads-
tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen
6 Interfaces
6.1 Interface Setup
Interface
IRQ
Adress
COM1
4
3F8h
RFID (Touch)
3
2F8h
Pos : 26 /D atent ec hni k/Schnitts tell en/Spannungs versorgung/Spannungs versorg ung f ür VMT60xx- Seri e @ 2\ mod_1260450284020_6. doc @ 6853 @
6.2 24V DC Power Supply
The supply voltage is provided via a lead-through terminal including a screw connection (Phoenix
Contact COMBICON MC 1,5/4-STF3.81). (The figure shows the socket inside the device)
Pin-Number
Signal-Name
1
PE
2
0V DC
3
Ignition contact
4
24V DC
Voltage tolerance
•Input voltage: 24 V DC ± 20%.
Current consumption
The current consumption of this device depends on the equipment version
(e.g. if a heater or WLAN, etc. is installed.)
•
Switch-on current: 7A (1ms)
•
Standby current consumption: 0.25mA
•
Regular operation: 1.3A without heater
(without any additional load on the USB ports and without delivering the +5V supply for the scanner)
Note:
The power supply can be protected with a slow-blow fuse of up to 4A.
Note:
The typical power consumption of this device is indicated in the "Technical
details" chapter.