The Ads Security A180 Series provides top-notch protection for your home or business. Easily set up and manage the system with the User Manual available for free download from manualshive.com. Stay secure with this advanced security solution.
MOUNTVIEW TECH AUSTRALIA PTY LTD
Wireless Alarm system’s
manual
ADS‐A180 Series
ADS
Security
1/11/2011
Page 1: ...MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1 11 2011...
Page 2: ...the antenna Extend the length of the antenna if you need better results Keep this booklet in a safe place This alarm system is designed to be and acts as a theft deterrent This system like any other c...
Page 3: ...Without electricity Away LED Always lit Alarm system is on away mode Home LED Always lit Alarm system is on home mode Set LED Always lit Alarm system is on set mode Cut LED Always lit The phone line i...
Page 4: ...nd the alarm signal We suggest using the window Door gap sensors as your primary alarm triggers They are reliable and if installed correctly can safeguard doors and windows from being opened without y...
Page 5: ...and exit points If the room has several entry points try to cover as many of these as practicable A visible PIR motion sensor can be a great deterrent to intruders but on the other hand skilled intru...
Page 6: ...th passwords the same or different Change the password for the keypad by command 2 new password make sure put away the watch dog after changing password Intruder who knows this command will operate th...
Page 7: ...he trigger should be placed on the movable side with a gap not exceeding 1CM The door window sensors can attach most surfaces by double sided mounting tape Installing wireless keypad Install the keypa...
Page 8: ...r and code the sensor to different ZONE Most user use zone 01 for remote controllers and keypads Zone number can be any two digital numbers between 01 and 90 2 Under CODE mode key in the zone number s...
Page 9: ...d sensors will set off the alarm after pre set time The zone number can be any two digital numbers between 01 and 90 The command pattern is 29 Zone NO 3 To set delay how many seconds the command is 34...
Page 10: ...25 Change the password New password default password 1234 26 after how many rings the alarm system will pick up your call 01 02 03 12 Recommend you set 12 rings if you have answer machine 27 How long...
Page 11: ...ommand Function 1 Arm one beep if successfully 2 Disarm one beep if successfully 3 Siren sounds for 3 seconds Listen in for 30 seconds Key in for continue return 6 TROUBLESHOOTING Problem Probable Rea...
Page 12: ...ove one detector next to panel and try identify the interfering source and eliminate it check Panel power whether plugged well 7 Technical Parameters ADS A180 Main Panel Operating voltage DC12V Averag...
Page 13: ...ission Current 20mA Frequency 433MHZ Transmission Distance less 80M Detective Speed 0 3 3m s Detective Distance 5 12M Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 40 Hum...