background image

          

After

 

sale

 

support

 

for

 

ebay

 

buyer

                   

EMAIL:

 

[email protected]

                        

6

 

7.

 

inner

 

Circuit

 

Board

 

 
 

3.

  

INSTALLATION

 

Open

 

the

 

alarm

 

kit

 

and

 

determine

 

where

 

each

 

piece

 

is

 

to

 

be

 

located.

 

The

 

PIR

 

sensors

 

usually

 

mounted

 

high

 

on

 

a

 

wall

 

and

 

directed

 

into

 

the

 

room

 

requiring

 

protection

 

such

 

as

 

a

 

lounge

 

room

 

or

 

hallway.

 

The

 

main

 

panel

 

is

 

usually

 

located

 

somewhere

 

within

 

1

 

meter

 

of

 

a

 

power

 

point.

 

The

 

sensors

 

must

 

not

 

be

 

located

 

more

 

than

 

80

 

metres

 

from

 

the

 

main

 

panel.

 

Installing

 

the

 

ADS

A180

 

main

 

panel:

  

Connect

 

the

 

power

 

supply,

 

telephone

 

line,

 

internal

 

siren,

 

and

 

antenna.

 

Switch

 

ON/OFF

 

to

 

ON

 

position.

 

Remember:

 

test

 

the

 

whole

 

system

 

before

 

you

 

fasten

 

them

 

on

 

the

 

position.

  

Installing

 

wireless

 

PIR

 

sensors:

   

Installation

 

height

 

is

 

about

 

2.2

 

meters

 

above

 

ground

 

and

 

you

 

need

 

consider

 

the

 

best

 

coverage.

 

(Ref:

 

page3)

 

Installing

 

wireless

 

Door/Window

 

sensor:

 

The

 

transmitter

 

should

 

be

 

installed

 

on

 

the

 

fixed

 

frame

 

and

 

the

 

trigger

 

should

 

be

 

placed

 

on

 

the

 

movable

 

side

 

with

 

a

 

gap

 

not

 

exceeding

 

1CM.

 

The

 

door/window

 

sensors

 

can

 

attach

 

most

 

surfaces

 

by

 

double

 

sided

 

mounting

 

tape.

 

Installing

 

wireless

 

keypad:

 

Install

 

the

 

keypad

 

at

 

main

 

entrance

 

and

 

must

 

under

 

cover.

 

Keep

 

the

 

watch

 

dog

 

separately

 

in

 

a

 

safe

 

place.

 

You

 

need

 

plug

 

watch

 

dog

 

on

 

when

 

you

 

change

 

the

 

password

 

in

 

the

 

future.

 

Installing

 

Dual

 

beam

 

infrared

 

barrier:

  

Connect

 

the

 

power

 

cable

 

as

 

demonstration.

 

“+”pole

 

connect

 

power

 

adapter’s

 

red

 

cable,

 

”pole

 

connect

 

power

 

adapter’s

 

black

 

cable.

 

Screw

 

both

 

parts

 

onto

 

the

 

position

 

where

 

you

 

prefer.

 

And

 

make

 

sure

 

the

 

same

 

level

 

of

 

two

 

parts.

 

Turning

 

the

 

barrier

 

slightly

 

to

 

make

 

sure

 

two

 

parts

 

are

 

facing

 

each

 

other.

 

 

4.

  

PROGRAMMING

 

ADS

A180

 

 

PASSWORD:

  

The

 

default

 

password

 

is

 

1234.

 

We

 

strongly

 

recommend

 

choosing

 

a

 

new

 

password

 

as

 

soon

 

as

 

possible.

 

Command:

  

25

 

*

 

new

 

password

 

#

 

(must

 

under

 

set

 

mode)

 

SET

 

mode:

 

Key

 

in

 

password

 

then

 

presses

 

the

 

SET

 

button.

 

The

 

most

 

programming

 

needs

 

under

 

SET

 

mode.

 

Press

 

the

 

SET

 

button

 

to

 

return.

 

System

 

will

 

return

 

automatically

 

if

 

there

 

is

 

no

 

operation

 

in

 

30

 

seconds

 

during

 

SET

 

mode

 

condition.

 

Summary of Contents for A180 Series

Page 1: ...MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1 11 2011...

Page 2: ...the antenna Extend the length of the antenna if you need better results Keep this booklet in a safe place This alarm system is designed to be and acts as a theft deterrent This system like any other c...

Page 3: ...Without electricity Away LED Always lit Alarm system is on away mode Home LED Always lit Alarm system is on home mode Set LED Always lit Alarm system is on set mode Cut LED Always lit The phone line i...

Page 4: ...nd the alarm signal We suggest using the window Door gap sensors as your primary alarm triggers They are reliable and if installed correctly can safeguard doors and windows from being opened without y...

Page 5: ...and exit points If the room has several entry points try to cover as many of these as practicable A visible PIR motion sensor can be a great deterrent to intruders but on the other hand skilled intru...

Page 6: ...th passwords the same or different Change the password for the keypad by command 2 new password make sure put away the watch dog after changing password Intruder who knows this command will operate th...

Page 7: ...he trigger should be placed on the movable side with a gap not exceeding 1CM The door window sensors can attach most surfaces by double sided mounting tape Installing wireless keypad Install the keypa...

Page 8: ...r and code the sensor to different ZONE Most user use zone 01 for remote controllers and keypads Zone number can be any two digital numbers between 01 and 90 2 Under CODE mode key in the zone number s...

Page 9: ...d sensors will set off the alarm after pre set time The zone number can be any two digital numbers between 01 and 90 The command pattern is 29 Zone NO 3 To set delay how many seconds the command is 34...

Page 10: ...25 Change the password New password default password 1234 26 after how many rings the alarm system will pick up your call 01 02 03 12 Recommend you set 12 rings if you have answer machine 27 How long...

Page 11: ...ommand Function 1 Arm one beep if successfully 2 Disarm one beep if successfully 3 Siren sounds for 3 seconds Listen in for 30 seconds Key in for continue return 6 TROUBLESHOOTING Problem Probable Rea...

Page 12: ...ove one detector next to panel and try identify the interfering source and eliminate it check Panel power whether plugged well 7 Technical Parameters ADS A180 Main Panel Operating voltage DC12V Averag...

Page 13: ...ission Current 20mA Frequency 433MHZ Transmission Distance less 80M Detective Speed 0 3 3m s Detective Distance 5 12M Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 40 Hum...