background image

The information in this document is subject to change without notice and should not be construed as a commitment 
by ADP, Inc.   ADP is not responsible for any technical inaccuracies or typographical errors which may be contained 
in this publication. Changes are periodically made to the information herein, and such changes will be incorporated 
in new editions of this publication. ADP may make improvements and/or changes in the product and/or the programs 
described in this publication at any time without notice. 

This document or any part thereof may not be reproduced in any form without the written permission of Kronos 
Incorporated. All rights reserved. © 1999, 2000, Kronos Incorporated.

ADP provides this publication "as is" without warranty of any kind, either express or implied, including, but not limited 
to, the implied warranties of merchantability or fitness for a particular purpose.

ADP is a registered trademark of ADP of North America, Inc. eTIME is a registered trademark of Automatic Data 
Processing, Inc.  

When using and applying the information generated by ADP products, customers should ensure that they comply 
with the applicable requirements of federal and state law, such as the Fair Labor Standards Act.

FCC Compliance

After testing, this equipment complies with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. 
These limits provide reasonable protection against harmful interference when this equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not 
installed and used in accordance with the instruction manual, it can cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which 
case, the user, and not Kronos Incorporated, is required to correct the interference.

Canadian DOC Compliance

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in 
the Radio Interference Regulations of the Canadian Department of Communications.

Cet appareil numérique respecte les limites de rayonnement de bruits radioélectriques applicables aux appareils 
numériques de classe A, prévues au Règlement sur le matériel brouilleur du ministère des Communications du 
Canada.

EN 55022 (CISPR 22)

This product is a Class A product. In a domestic environment, it may cause radio interference in which case the user 
may be required to take adequate measures.

Published by ADP, Inc.

ADP, Inc.

One ADP Boulevard
Roseland, NJ 07068

For more information, see the ADP, Inc. Web page:

http://www.ADP.com

Document Revision History  

Document Revision

 Release Date

A

June  2000

B

July  2000

Summary of Contents for 14.4Kbps

Page 1: ...Document Part Number 4701357 002 Document Revision B This manual provides installation and troubleshooting instructions for the 14 4Kbps Modem option 14 4Kbps Modem Option Installation Guide ...

Page 2: ...quipment complies with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits provide reasonable protection against harmful interference when this equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it can cause harmful interfer...

Page 3: ...ts Introduction 5 Overview of the 14 4Kbps Modem Option 6 Installing the 14 4Kbps Modem Option 7 Hardware Installation 7 Terminal Configuration 8 Troubleshooting 11 Timeclock Configuration Quick Reference 13 ...

Page 4: ...iv ADP Incorporated ...

Page 5: ...ndustry standard modem protocols with speeds other than 14 4Kbps The 14 4Kbps Modem option is compatible with timeclocks equipped with the following Main boards with a part number of 6600177 00X or 6600186 00X Rev A or later Boot PROM software version 2B00 or later for the 6600177 00X board or 3B00 or later for the 6600186 00X board FLASH EEPROM time and attendance application version 400 5C or la...

Page 6: ...tion about the modem option The LEDs are described as follows Ring Indicator RI The RI LED lights when the RS 485 modem option is being called from eTIME Carrier Detect CD The CD LED lights when the RS 485 modem option has detected a carrier signal thus signifying a connection between modems Receive Data RD The RD LED lights when the timeclock is receiving data from eTIME Send Data SD The SD LED l...

Page 7: ...timeclock configuration Follow the steps in the two sections that follow to install the 14 4Kbps Modem option Hardware Installation To install the 14 4Kbps Modem option 1 Collect the timeclock data using the eTIME software 2 Using an 8 32 security head wrench unlock and open the timeclock s front cover a If the timeclock is equipped with a 12 VDC lead acid backup battery disconnect the backup batt...

Page 8: ...main board b Reconnect the timeclock to its external power source If the timeclock is powered using a DC wall supply plug the wall supply s cable into connector J1 on the 6600177 board or J3 on the 6600186 board Terminal Configuration To configure the timeclock 1 At the timeclock enter Command Mode and then enter command 90 Command 90 allows you to access Program Mode which is where you configure ...

Page 9: ... if the message NO MODEM ALLOCATED appears here it indicates that the modem has not been enabled and thus is not recognized Similarly a NO MODEM ACTIVE message indicates that the modem has been enabled but is not responding For more information see the Troubleshooting section that follows An INTERNAL 2400b MODEM message indicates a modem has been found and is responding However the responding mode...

Page 10: ...e plus 4 for the end of text indicator 10 At the eTIME site be sure that the modem is connected to the PC and working properly Follow the instructions supplied by the modem manufacturer when making this connection 11 Connect the eTIME modem to a live phone line Note Between the eTIME PC and eTIME modem it is recommended that you turn off hardware RTS CTS flow control for DOS and turn it on for Win...

Page 11: ...odule produces an error message at the timeclock The currently installed modem either the 2400 baud modem or the 14 4Kbps Modem option is failing its internal loopback test This command should not be run while the modem is communicating with another modem Verify the modem board installation and the timeclock setup for the respective modem 2400 baud modem or 14 4Kbps Modem option These messages app...

Page 12: ... for a lower rate modem such as V 22bis If the modem negotiation is timing out configure your eTIME PC modem and 14 4Kbps Modem option for the same telephone line rate that is 1200 2400 9600 or 14 4 Communication is initially established but the modems hang up immediately Verify that the error correction and data compression settings on off are the same for the eTIME PC modem and the 14 4Kbps Mode...

Page 13: ...or correction data compression Procedure 10 Step 9 6 Exit Program Mode and return to Command Mode 7 Use command 118 to verify that the timeclock recognizes a modem and then confirm all of your modem selections 8 Close and secure the timeclock s front cover 9 Configure all other timeclocks which are connected at the remote site by way of RS 485 with these values Modem Option Modem not installed Con...

Page 14: ...14 4Kbps Modem Option Installation 14 ADP Incorporated ...