Installation
•
13
2.7.2
JP2: Cold Junction Sensor Selection
JP2 is used to set the usage of cold junction sensor. Note that this
jumper is used with JP1 together. The following diagram shows the
possible configurations.
l
No use the C.J. Sensor (Default)
l
Connect the C.J. sensor to AD Channel #0 under Differential
Input mode. Note that if the JP1 is wrongly set as SE mode, the
C.J sensor is connected to CH#0 and the CH#16 is connected to
ground plane.
l
Connect the C.J. Sensor to AD Channel #0 under Single-Ended
Input mode. CH#16 is used as normal single-ended input.
CJ
JP2: Do not Use the C.J. Sensor
Normal
CJ
JP2: Use the C.J. Sensor ( D.I. mode)
Normal
CJ
JP2: Use the C.J. Sensor (S.E. mode)
Normal
DI
JP1: Differential Input
SE