20
•
Operation Theoreym
4.1.3.1 Scan Timing and Procedure
There are 4 counters that need to be specified prior to programmable
scans:
Counter
Name
Width Description
Notes
SI_counter
24-bit
S
can
I
nterval
,
which
defines the interval
between each scan.
S
can
I
nterval =
SI_counter /
Time-
base*
SI2_counter
24-bit
S
ampling
I
nterval,
which defines the
interval between
each sampled
channel.
S
ampling
I
nterval =
SI2_counter /
Timebase*
PSC_counter
24-bit
P
ost
S
can
C
ounts,
which defines how
many scans to be
performed with re-
spect to each trig-
ger.
Delay_counter 16-bit
Define the delay
time for scan after
trigger.
Delay
Time =
(Delay_counter /
Timebase*
),
Timebase*=40M for DAQ/PXI-2500 Series
Table 4.1.4 Summary of Counters for Programmable Scan
The relationship between counters and acquisition timing is illustrated in
Figure 4.1.1.