background image

18

HPERC-IBR-M Setup

1.16.2

P3 Pin Definitions

 Table 1-8 Provides the pin definitions and signal maps for the P3 Military Connector.

P3 

Pin

Interface

Signal

Signal Description

1

VGA

VGA_VSYNC

Vertical Sync

2

Ground

GND

Ground

33

Ground

GND

Ground

3

VGA

VGA_DDC_SCL

Display Data Channel - Serial 
Clock

4

VGA

VGA_DDC_SDA

Display Data Channel - Serial 
Data

5

Ground

GND

Ground

6

VGA

RED

Red Analog Output

18

Ground

GND

Ground

7

VGA

GREEN

Green Analog Output

21

Ground

GND

Ground

14

VGA

BLUE

Blue Analog Output

30

Ground

GND

Ground

8

VGA

HSYNC

Horizontal Sync

9

Power

P3V3_S

+3.3 Volts Standby

10

Power

P3V3_S

+3.3 Volts Standby

11

Ground

GND

Ground

12

Power

P3V3_S

+3.3 Volts Standby

13

Power

P3V3_S

+3.3 Volts Standby

15

Power

P3V3_S

+3.3 Volts Standby

38

Ground

GND

Ground

24

Control/Indicator

PCIe_ETH_5/5_LED1

Ethernet LED

99

Ground

GND

Ground

114

Control/Indicator

PCIe_ETH_4/5_LED1

Ethernet LED

99

Ground

GND

Ground

121

Control/Indicator

PCIe_ETH_3/5_LED1

Ethernet LED

99

Ground

GND

Ground

16

Gigabit Ethernet 4

GbE5_MDI0_N

Ethernet4 MDI0 Negative

17

Gigabit Ethernet 4

GbE5_MDI0_P

Ethernet4 MDI0 Positive

18

Ground

GND

Ground

19

Gigabit Ethernet 4

GbE5_MDI1_N

Ethernet4 MDI1 Negative

20

Gigabit Ethernet 4

GbE5_MDI1_P

Ethernet4 MDI1 Positive

21

Ground

GND

Ground

22

Gigabit Ethernet 4

GbE5_MDI2_N

Ethernet4 MDI2 Negative

23

Gigabit Ethernet 4

GbE5_MDI2_P

Ethernet4 MDI2 Positive

100

Gigabit Ethernet 4

GbE5_MDI3_N

Ethernet4 MDI3 Negative

101

Gigabit Ethernet 4

GbE5_MDI3_P

Ethernet4 MDI3 Positive

25

Serial 1

RS422_TX1_N

Transmit Data Negative

26

Serial 1

RS422_TX1_P

Transmit Data Positive

27

Serial 1

RS422_RX1_N

Receive Data Negative

28

Serial 1

RS422_RX1_P

Receive Data Positive

29

NC

NA

NA

Table  1-8: P3 Connector Pin Signals

Summary of Contents for HPERC-IBR-MC

Page 1: ...Advance Technologies Automate the World HPERC IBR MC MH High Performance Extreme Rugged Computer System User s Manual Manual Rev 1 00 Revision Date December 20 2016 Part No 50 1Z178 1000...

Page 2: ...ii Revision History Revision History Revision Reason for Change Date 1 00 Initial release 20 12 2016...

Page 3: ...intellectual property right If you intend to use ADLINK products in or as medical devices you are solely responsible for all required regulatory compliance including without limitation Title 21 of the...

Page 4: ...iv Preface This page intentionally left blank...

Page 5: ...x 7 1 11 Setup Steps 8 1 12 Setting Up the Work Space 8 1 13 Installing Mounting Screws 9 1 14 Connecting Peripherals 12 1 15 P1 Military DC Power In Connector 13 1 16 P2 and P3 Military Connector 14...

Page 6: ...O 32 3 3 12H W Monitor 32 3 3 13Serial Port Console 33 3 3 14AMI Graphic Output Protocol Policy 35 3 3 15MXM 3 0 Hybrid Graphics 35 3 3 16Intel RC Drivers Version Detail 35 3 3 17CPU PPM Configuration...

Page 7: ...ories 7 Figure 1 4 Top and Front Views of MH Enclosure with Mounting Dimensions 9 Figure 1 5 Top and Front Views of MC Enclosure with Mounting Dimensions 10 Figure 1 6 Bottom View of MC Enclosure with...

Page 8: ...viii List of Figures This page intentionally left blank...

Page 9: ...without GPGPU 5 Table 1 3 System Power Requirements with GPGPU 6 Table 1 4 Environmental Requirements 6 Table 1 5 I O Panel Connectors Refer to Figure 1 7 for connector locations 13 Table 1 6 P1 Mili...

Page 10: ...x List of Tables This page intentionally left blank...

Page 11: ...with your desired OS The instructions provided in this guide include X Removing the HPERC IBR M from the shipping container and inspecting the accesso ries X Connecting peripherals to the HPERC IBR M...

Page 12: ...n processor One VGA two DVI and one HDMI GPGPU General purpose GPU via MXM slot PCIe x16 Gen3 GT745M with 2 GB GDDR5 128 bit RAM GTX950M with 2 GB GDDR5 128 bit RAM Gigabit Ethernet Four Intel I210 10...

Page 13: ...able 514 6C X Category 9 Helicopter vibration exposure General MIL STD 810G Figure 514 6C 10 Category 11 Rail cargo vibration exposure MIL STD 810G Figure 514 6D 9 Category 21 Shipboard random vibrati...

Page 14: ...77 PCH DMI FDI 2x SATA 2x DVI D VGA HD Audio 6x USB 2 0 2x eSATA PCIe x4 PCIe Switch 1 2 XIO2001 PCIe to PCI Bridge PCIe x1 PCI 104 Express Type B Connector PCI 32bit 33 66MHz PCIe x4 PCI 104 Express...

Page 15: ...le operating configuration includes the In rush configuration as well as one SATA 2 5 HDD with Windows 7 and one USB keyboard and mouse X BIT Burn In Test operating configuration is the same as the Id...

Page 16: ...icient operating and storage condition ranges required for this system Parameter 2 1GHz CPU i7 3612QE Input Type 24 VDC Regulated DC Windows Idle mode 24V 1 27A 30 48W ESIT disabled 24V 1 33A 31 92W W...

Page 17: ...HPERC IBR M Accessories sold separately See Figure 1 3 Figure 1 3 HPERC IBR M Unit with Accessories SATA Cooling Fins pre installed on MH version only Mounting Brackets Breakout Cables HPERC Accessor...

Page 18: ...e the specified operating temperature limits if the airflow through the cooling solution is restricted Select workbench location The workbench location should be a flat clean surface for setup and ope...

Page 19: ...HPERC IBR M Setup 9 HPERC IBR M HPERC IBR MH Figure 1 4 Top and Front Views of MH Enclosure with Mounting Dimensions...

Page 20: ...plate is flat to a tolerance of 0 1 mm across the diagonal It is recom mended that the surface on which the HPERC IBR MC will be mounted is flat to a tolerance of 0 15 mm across the diagonal Figure 1...

Page 21: ...for surface wall mounting or heat sink HPERC IBR MC only Mounting holes A and B are shown below in Figure 1 6 Note the recommended torque values and maximum depth of hole B Mounting Hole A Size M4 thr...

Page 22: ...tors Refer to Figure 1 7 for locations and descriptions of the connectors before making connections or powering on the HPERC IBR M Connect the USB or PS2 keyboard to the corresponding connector on the...

Page 23: ...connector provides signals for Ethernet Ports USB 2 0 Serial Ports Reset Switch Ethernet LEDs Power LED SATA Activity LED UNDIO Power Switch Audio In Out P3 Military Connector This military connector...

Page 24: ...nectors P2 and P3 on the HPERC IBR M Each table lists the P2 or P3 pin numbers the signal names and descriptions and the corresponding pins of the internal IO boards HIBR and Interface Board Figure 1...

Page 25: ...15 USB 2 0 Port 4 P5V_USB4 5 Volts Power 16 USB 2 0 Port 5 P5V_USB5 5 Volts Power 17 Serial 4 RS422_TX4_N Transmit Data Negative 18 Serial 4 RS422_TX4_P Transmit Data Positive 19 Serial 4 RS422_RX4_N...

Page 26: ...Port 20 56 Ground GND Ground 57 81 NC NA NA 71 User Defined IO UDNIO5 User Input Output Port 5 72 User Defined IO UDNIO6 User Input Output Port 6 73 Ground GND Ground 74 User Defined IO UDNIO7 User In...

Page 27: ...P Transmit Data Positive 109 Serial 5 RS422_RX5_N Receive Data Negative 110 Serial 5 RS422_RX5_P Receive Data Positive 111 Serial 7 RS422_TX7_N Transmit Data Negative 112 Serial 7 RS422_TX7_P Transmit...

Page 28: ...24 Control Indicator PCIe_ETH_5 5_LED1 Ethernet LED 99 Ground GND Ground 114 Control Indicator PCIe_ETH_4 5_LED1 Ethernet LED 99 Ground GND Ground 121 Control Indicator PCIe_ETH_3 5_LED1 Ethernet LED...

Page 29: ..._N1 Digital Display Interface Port B TMDS Data 1 Negative 53 Ground GND Ground 54 DVI 1 DDIB_P0 Digital Display Interface Port B TMDS Data 2 Positive 55 DVI 1 DDIB_N0 Digital Display Interface Port B...

Page 30: ...LK_MS_CON Mouse Clock 66 PS 2 Mouse DAT_MS_CON Mouse Data 76 NC NA NA 67 PS 2 Keyboard CLK_KBD_CON Keyboard Clock 68 PS 2 Keyboard DAT_KBD_CON Keyboard Data 79 Ground GND Ground 69 PS 2 Mouse Keyboard...

Page 31: ...ound GND Ground 112 Gigabit Ethernet 3 GbE4_MDI2_N Ethernet2 Negative 113 Gigabit Ethernet 3 GbE4_MDI2_P Ethernet2 Positive 30 Ground GND Ground 31 Gigabit Ethernet 3 GbE4_MDI3_N Ethernet3 MDI3 Negati...

Page 32: ...the HPERC IBR M satisfactorily powers on To enter the BIOS Setuppress the Del key during power on self test POST Use BIOS Setup during the initial boot to set the desired options You should see POST c...

Page 33: ...sealing any of the openings on the HPERC IBR M enclosure may compromise the IP67 ingress rating performance of the system It is strongly recommended to return the sys tem to ADLINK for servicing If yo...

Page 34: ...24 Internal Components This page intentionally left blank...

Page 35: ...on Processor Information IGFX VBIOS Version Total Memory PCH Information ME Information System Language System Management System Date System Time Watch Dog Timer Intel PXE option ROM ACPI Settings Tru...

Page 36: ...re Options Description Name Info only Chipset String CPU brand string Info only CPU Brand String Frequency Info only Standard CPU frequency Processor ID Info only CPUID Stepping Info only CPU Stepping...

Page 37: ...H MM SS Presented as a 24 hour clock setting in hours minutes and seconds Feature Options Description Enable ACPI Auto Configuration Disabled Enabled Enable Disable BIOS ACPI Auto Configuration Enable...

Page 38: ...splay L2 cache size L3 Cache Info only Display L3 cache size Hyper threading Disabled Enabled Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology and Disabled for other OS OS...

Page 39: ...Enable or Disable SATA Port Hot Plug Disabled Enabled Designates this port as Hot Pluggable External SATA Disabled Enabled External SATA Support Feature Options Description Intel Rapid Start technolog...

Page 40: ...r Disables Intel R TXT LT support Feature Options Description ME FW Version Info only ME FW Mode Info only ME FW Type Info only ME FW SKU Info only Feature Options Description Intel R Anti Theft Techn...

Page 41: ...t 10 sec 20 sec 30 sec 40 sec USB mass storage device start unit command time out Device power up delay Auto Manual Maximum time the device will take before it properly reports itself to the host cont...

Page 42: ...tions Description Serial Port 1 Configuration Info only Serial Port Disabled Enabled Enable or Disable Serial Port COM Device Setting Info only Change Setting Auto IO 3F8 IRQ 4 IO 3F8 IRQ 3 4 5 6 7 9...

Page 43: ...ettings COM3 Info only Console Redirection Disabled Enabled Console Redirection enable or disable Console Redirection Settings Submenu The settings specify how the host computer and the remote compute...

Page 44: ...k Space Select parity Stop Bits 1 2 Select number of stop bits Flow Control None Hardware RTS CTS Select flow control VT UTF8 Combo Key Support Disabled Enable Enable VT UTF8 combination key support f...

Page 45: ...only Output interface Brightness setting Info only Output interface Feature Options Description MXM 3 0 Support Disabled Enable Enable Disable the MXM 3 0 support Feature Options Description Intel CPU...

Page 46: ...bled Disabled Enable Disable CPU C7 ACPI C3 report to OS Feature Options Description PCH LAN Controller Disabled Enable Enable or Disable onboard NIC PCI Express Configuration Submenu PCI Express opti...

Page 47: ...ns settings Memory Configuration Submenu Memory options settings Feature Options Description Graphics Info only IGFX VBIOS version Info only Primary Display Auto IGFX PEG PCIE Select which of Auto IGF...

Page 48: ...re Hardware Spread is controlled by chip Software Spread is controlled by BIOS Feature Options Description PEG0 Info only PEG0 Gen X Auto Gen1 Gen2 Gen3 Configure PEG0 B0 D1 F0 Gen1 Gen3 Feature Optio...

Page 49: ...on Policy Default Place First Place Last Controls the placement of newly detected UEFI boot options CSM16 Configuration Submenu CSM16 configuration Enable Disable Option ROM execution settings etc CSM...

Page 50: ...policy for devices other than Network Storage or Video Feature Options Description Administrator Password Enter password User Password Enter password Feature Options Description Save Changes and Exit...

Page 51: ...le surfaces and or recommended mountings Z If the equipment will not be used for long periods of time turn off and unplug the equip ment from its power source 5 Never attempt to fix the equipment Equi...

Page 52: ...42 Safety Instructions This page intentionally left blank...

Page 53: ...408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 Chi...

Reviews: